2.1.3 Australian Requirements
To be installed in accordance with AS 5601, local authority, gas, electricity, and any other relevant
statutory regulations.
2.2
Power Requirements
MODEL
FPEL14
FPEL14
FPEL14
FPEL14
FPEL14
FPEL14
FPEL17
FPEL17
FPEL17
FPEL17
FPEL17
FPEL17
If this appliance is permanently connected to fixed wiring, it must be connected by
means of copper wires having a temperature rating of not less than 167°F (75°C).
This appliance must be connected to a power supply having the same voltage and
phase as specified on the rating plate located on the inside of the appliance door.
All wiring connections for this appliance must be made in accordance with the
wiring diagram(s) furnished with the appliance.
affixed to the inside of the appliance door when installing or servicing this
equipment.
Three (3) Phase Requirements
MINIMUM WIRE
WIRE
VOLTAGE
SERVICE
AWG
208
3
240
3
480
3
220/380
4
240/415
4
230/400
4
208
3
240
3
480
3
220/380
4
240/415
4
230/400
4
NOTICE
DANGER
DANGER
2-3
AMPS
SIZE
(per leg)
(mm)
6
(4.11)
39
6
(4.11)
34
8
(2.59)
17
6
(4.11)
21
6
(4.11)
20
6
(4.11)
21
6
(4.11)
48
6
(4.11)
41
6
(4.11)
21
6
(4.11)
26
6
(4.11)
24
6
(4.11)
25
Refer to the wiring diagram(s)