All wiring connections for this appliance must be made in accordance with the
wiring diagram(s) furnished with the appliance.
affixed to the inside of the appliance door when installing or servicing this
equipment.
The appliance area must be kept free and clear of combustible material at all times.
Do not block the area around the base or under the fryers.
All installation and service on FRYMASTER equipment must be performed by qualified, certified,
licensed, and/or authorized installation or service personnel.
Service may be obtained by contacting a local Frymaster DEAN Factory Authorized Servicer.
In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the
power switch OFF. Do not attempt to start the fryer(s) until power is restored.
A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible
construction. A minimum of 24 inches (61cm) should be provided at the front of the equipment for
servicing and proper operation.
Connections should be made by means of an approved, flexible-metallic or rubber-covered electrical
cable and quick-disconnect plug. The fryers may be installed with "hard-wired" connections, but
use of quick-disconnect plugs will facilitate service if required. Connections are made to the fryer
power input terminal block located in the lower back of the fryer(s).
2.2

Power Requirements

MODEL
FPRE117
FPRE117
FPRE122
FPRE122
FPRE217 (Per Vat)
FPRE217 (Per Vat)
FPRE222 (Per Vat)
FPRE222 (Per Vat)
RE Series Marine electric fryers are equipped with a filter system that requires a separate 120VAC
or 220VAC depending on configuration, single-phase, 3-wire, 20 amp service (refer to wiring
diagram on page 7-15).
If this appliance is permanently connected to fixed wiring, it must be connected by
means of copper wires having a temperature rating of not less than 167°F (75°C).
DANGER
DANGER
WARNING
Use copper wire ONLY, suitable for at least 167°F (75°C)
VOLTAGE
PHASE
440
3
480
3
440
3
480
3
440
3
480
3
440
3
480
3
NOTICE
Refer to the wiring diagram(s)
MINIMUM WIRE
WIRE
SIZE
SERVICE
AWG
3
6
3
6
3
6
3
6
3
6
3
6
3
6
3
6
2-2
AMPS
(per leg)
mm
(4.11)
23
(4.11)
21
(4.11)
29
(4.11)
27
(4.11)
23
(4.11)
21
(4.11)
29
(4.11)
27