6.2.4 Filtration Problems

Problem
Fryer filters after each
cook cycle.
Filter menu functions
won't start.
Controller displays
WAIT FOR FILTER.
Filter pump won't start
or pump stops during
filtering.
Filter Pump runs, but
oil return is very slow.
Controller displays
OIL IN DRAIN
PAN / CONFIRM
6.2.5 Auto Top-Off Problems
Problem
Frypots top off cold.
Frypots won't top off.
One vat doesn't top off.
Probable Causes
Filter prompt setting incorrect.
Temperature too low.
Another function is still in process.
A. Power cord is not plugged in or circuit
breaker is tripped.
B. Pump motor has overheated causing
the thermal overload switch to trip.
C. Blockage in filter pump.
Improperly installed or prepared filter pan
components or cold oil.
Drain valve open or possibility that oil is in
drain pan.
Probable Causes
Incorrect setpoint.
A. Fryer temperature too low.
B. Oil is too cold.
C. JIB out of oil
D. Service required error exists
A. Filter error exists.
B. Service required error exists
C. Solenoid, pump, pin issue, RTD or
ATO issue.
Corrective Action
Change the filter prompt setting.
Ensure fryer is at setpoint before starting;
ensure the controller is ON.
Wait until the previous function ends to
start another filtration cycle.
A. Verify that the power cord is fully
plugged in and the circuit breaker is
not tripped.
B. If the motor is too hot to touch for
more than a few seconds, the
thermal
probably tripped. Allow the motor
to cool at least 45 minutes then press
the Pump Reset Switch. (See page 5-
4)
C. Call your FAS for assistance.
Remove the oil from the filter pan and
replace the filter paper, ensuring that
the filter screen is in place under the
paper.
Verify that O-rings are present and in
good condition on filter pan connection
fitting.
Press
directions for FILL VAT FROM
DRAIN PAN.
Corrective Action
Ensure setpoint is correct.
A. Fryer
setpoint.
B. Ensure that the oil in the JIB is
above 70°F (21°C).
C. Ensure the JIB is not out of oil and
supply line is in the JIB. Replace JIB
and press the
prompted to reset top off system.
If problem persists call your FAS for
assistance.
D. Call your FAS for assistance.
A. Clear filter error properly. If
problem persists call your FAS for
assistance.
B. Call your FAS for assistance.
C. Call your FAS for assistance.
6-4
overload
switch
has
(CONFIRM) and follow
temperature
must
be
button when
at

Advertisement

Table of Contents
loading