Installation Site Of The Remote Control; Assembling; Domestic Ventilation Unit - Vaillant recoVAIR/3 SERIES Operating And Installation Manual

Recovair/3 series domestic ventilation unit with heat recovery and remote control
Table of Contents

Advertisement

100
1000
Fig. 4.1 Required minimum distances/installation free spaces
– The attached condensed water drain trap is destined
to compensate pressure between the device and the
installation room, for that reason it must always be
filled with clear water.
– For hygienic reasons, it must not be directly connect-
ed to the odour trap of the waste water system. En-
sure an air gap of at least 20 mm.
– For the installation, at least 10 cm of free space on the
side of the device must be provided.
– For installation, filter replacement and maintenance
works, about 1 m working space in front of the ventila-
tion unit is needed. Over and beneath the device at
least 30 cm are required (see also fig. 4.1).
– If the domestic ventilation unit is mounted on an inter-
nal wall, do not select a location directly above bed-
rooms due to possible sound transfer. Always choose
a location above a non-occupied room such as a hall
or bathroom.
– With wood-joist ceilings or similar you can provide ad-
ditional sound insulation by adding insulation between
the joists.
– Always ensure that the condensation water drain is
free running.
– To avoid annoyance by excessive noise select a
sound-absorbing hose for final connections from the
unit to the air outlets.
– Install a silencer. This will help to neutralise possible
noise transmission between the unit and the air duct-
ing and reduce annoyance by noise.
– Keep the air supply inlet at a sufficient distance from
discharge air, exhaust air and drain ventilation. Com-
ply with the legal building rules and regulations.
Installation Manual recoVAIR/3 0020062918_03
600
300
100
0-1˚
300
Assembly and installation 4
– When installing the fresh air input and discharge air
ducts you will have to ensure sufficient separation to
avoid that the discharged air being re-circulated into
the fresh air input.
According to VDI 6022 the minimum separation is
10 m.

4.2.2 Installation Site of the Remote Control

– The remote control must be mounted such that there
is enough space around it to complete the electric wir-
ing as well as easy operation of the control.
– The remote control must be installed inside the living
space in an easily accessible place. For further details
see section 4.8.
4.3

Assembling

4.3.1

Domestic Ventilation Unit

14
13
12
11
10
9
8
Fig. 4.2 Assembling recoVAIR VAR 275/3 and 350/3
Key
1
Air duct Outgoing air
2 Air duct Fresh air
3 Fresh air fan
4 Circuit board
5 Exhaust air fan
6 Condensate drain outlet
7 Electrical connection of
the 3-stage switch
The unit is equipped with a frost protecting sensor.
This sensor measures the temperature of the discharge
air. The fresh air fan is switched off if the discharge air
temperature falls below 3 °C.
Once switched off, the fresh air fan is only switched on
again when the discharge air temperature has risen
above 8 °C.
8 Outside air filter
9 Heat exchanger
10 Exhaust air filter
11 Mounting point Front
cladding
12 Air duct Exhaust air
13 Air duct Outside air
14 Bypass connection
1
2
3
4
5
6
7
19