Identification Plate; Safety Instructions And Regulations 2; Safety Instructions; Assembly And Installation - Vaillant recoVAIR/3 SERIES Operating And Installation Manual

Recovair/3 series domestic ventilation unit with heat recovery and remote control
Table of Contents

Advertisement

1.5

Identification Plate

Serial-no. 1234567890xxxxxx
VAR 275 / 3
P
Max
V
Max
dP
Max
T
Max.
Bar – Code
Fig. 1.1 Identification Plate
The identification plate is positioned below the unit. The
indications given on the identification plate have the fol-
lowing meaning:
Units
Value
Description
230 V ~50 Hz Mains voltage
P
210 W
Maximum electrical power consumption
max
V
275 m
3
/h
Maximum air volume flow
max
dP
170 Pa
Allowable pressure loss of the device at
max
V
Max
T
60
°
C
Maximum operating temperature
Max
Table 1.1 Explanation of identification plate
2
Safety Instructions and Regulations
2.1

Safety Instructions

Always observe the following safety instructions and
regulations.
Operating Manual recoVAIR/3 0020062918_03
Vaillant GmbH Remscheid / Germany
230V~ 50 HZ
210 W
275 m³ / h
170 Pa
60 °C
Notes on the documentation 1

Safety instructions and regulations 2

2.1.1

Assembly and Installation

The installation of the device can only be carried out by
a qualified expert technician. He/she will be responsible
for the correct installation and start-up.
He/she is also responsible for the inspection and the
corrective maintenance of the device as well as for the
changes in the air flow adjustment.
If the system is used for ventilation in locations with
room-dependent combustion equipment depending on
the room air, the corresponding flue gas extraction sys-
tems must be checked and maintained by a trained
technician. It is mandatory to prevent flue gas leakage
from the combustion equipment.
2.1.2

Operation

Note that the device can only be used if all ventilation
pipes of the device are connected and the entire device
is closed.
The unit must only be operated with the supplied filters
installed. Regularly check whether the filters are dirty
and damaged.
We recommend to visually check the filters every
6 months and to replace them every 12 months, or after
IPX2
2000 operating hours at the latest. If the system is to
be used for ventilation purposes in locations with room-
dependent combustion facilities, the corresponding flue
gas extraction systems must be checked and maintained
by suitably trained personnel.
2.1.3
Changes in the Environment of the Domestic
Ventilation Unit
a
Caution!
Do not make any changes to the unit or casing
which might impair the system functions!
Do not modify
- the unit,
– the outside air, fresh air, exhaust and discharge air
ducts, the pipes for condensation water and the unit
mains connection.
This also applies to alterations to structural elements in
the vicinity of the unit which might affect its operational
safety.
– do not obstruct the air inlets and outlets with doors,
ceilings, windows and walls even temporarily. Do not
cover the air inlets and outlets, e.g. with clothes or
similar. When laying floor materials, do not block or
reduce the vent apertures at the bottom of the doors.
To make alterations to the unit or to its environment,
you must refer to the suitably qualified expert techni-
cian who is qualified to do this work.
5