Assembly And Installation Of The Remote Control - Vaillant recoVAIR/3 SERIES Operating And Installation Manual

Recovair/3 series domestic ventilation unit with heat recovery and remote control
Table of Contents

Advertisement

To install the temperature sensor, proceed as follows
(see fig. 4.10):
• Remove the plug from the sensor hole in the outside
air duct.
• Push the temperature sensor through the hole into
the exhaust air duct.
a
Caution!
To ensure the correct bypass function the tem-
perature sensor must project at least 25 mm
into the exhaust air flow.
Fig. 4.11 Mounting position of the temperature sensor
After completing the electrical connection of the by-
pass, you can mount the bypass unit.
• Push the bypass into or over the both outside air con-
nections of the device as shown in fig. 4.10.
Make sure that the filter unit is aligned towards you.
• Check that the bypass is completely inserted.
• Plug in the mains plug into the plug socket.
Installation Manual recoVAIR/3 0020062918_03
Assembly and installation 4
4.8
Assembly and Installation of the Remote
Control
Normally the best siting of the remote control is in the
main living space at an inside wall at a height of about
1.5 m. There the controller is able to detect the circulat-
ing ambient air clearly and unimpeded from furniture,
curtains or other external influences. The position
should be selected so that neither air drafts from the
door or the window nor heat sources such as radiators,
chimney wall, TV or solar irradiation may directly influ-
ence the controller.
A connection with the ventilation unit is established via
a 2-core connection cable.
4
5
2
4
Fig. 4.12 Mounting of the remote control
Key
1
Casing
2 Mounting holes
3 Wall base
4 Cable bushings
5 Terminal strip
• Pull the casing (1) of the remote control from the wall
base (3).
• Make two mounting holes (2) with diameter 6 mm
(as shown in fig. 4.12) and insert the provided dowels.
• Pull the connection cable through one of the cable
openings (4).
• Fasten the wall base to the wall using the two supplied
screws.
• Connect the cable to the corresponding terminals
(eBUS "+" and "-") on the terminal connecting
strip (5).
• Place the casing (1) on to the wall base (2) such that
the pins at the back of the upper part locate into the
seats.
1
2
3
25