Service/Diagnostics Level - Vaillant recoVAIR/3 SERIES Operating And Installation Manual

Recovair/3 series domestic ventilation unit with heat recovery and remote control
Table of Contents

Advertisement

5 Start-up
Action
Display Meaning
HIGH
Set volume flow, 3rd stage
recoVAIR VAR
Default setting m
Click
Min m
Max m
Must value of the volume flow after the
activation of the special function "Ad-
vance Mode" with the key F.
AIR4
Set volume flow holiday
recoVAIR VAR
Default setting m
Click
Min m
Max m
Set volume flow after activation of the
special function "holidays" with the F
button, additionally in "OFF" mode.
AIR5
Min. volume flow with activated
bypass
recoVAIR VAR
Default setting m
Click
Min m
Max m
Minimum volume flow when the con-
nected bypass switches to summer
mode (without heat recovery).
STOV
Protective switching against
negative pressure
recoVAIR VAR
Click
Factory setting
ON = If one fan fails, the other fan is
also deactivated.
This protective switching prevents neg-
ative pressure as a result of only dis-
connecting the supply fan. If the pro-
tective switching against the low pres-
sure is activated, both fans are
switched off by the frost protection
function.
HEAT
No function
Click
FILT
Days till the next filter replacement
recoVAIR VAR
Default setting/days
Click
Min. days
Max. days
Adjusted in 30 day steps to which the
indication "FILT" is shown on the re-
mote control display. (Alarm output is
closed)
POL1
No function
POL2
Click
Table 5.1 Functions in the Installer Level (continued)
30
275/3 350/3
3
/h
275
350
3
/h
AIR2
AIR2
3
/h
325
400
275/3 350/3
3
/h
60
75
3
/h
50
70
3
/h
AIR2
AIR2
275/3 350/3
3
/h
110
140
3
/h
AIR1
AIR1
3
/h
HIGH
HIGH
275/3 350/3
OFF
OFF
275/3 350/3
180
180
30
30
180
180
Action
Display Meaning
C-AIR
Set volume flow correction
recoVAIR VAR
Default setting in %
Click
Min in %
Max in %
Adjustment of the set volume flow for
fresh air in order to produce a slightly
negative pressure in the building. At
low temperatures it prevents ice for-
mation due to condensation water on
the doors and windows.
C-RT
Room temperature correction
recoVAIR VAR
Factory setting in °C
Click
Min in °C
Max in °C
Correction of the room temperature
indicated on the display of the remote
control.
DAY
Desired value of the current day*
recoVAIR VAR
Factory setting
Click
Min
Max
MON
Desired value of the current month*
recoVAIR VAR
Factory setting
Min/month
Click
Max/month
YEAR
Desired value of the current year*
recoVAIR VAR
Factory setting
Click
Min/year
Max/year
Table 5.1 Functions in the Installer level (continued)
* Setting will be required if the automatic switching
from summer to winter time is to be activated.
5.1.2

Service/Diagnostics Level

The service/diagnostics level should help the installer
during the service.
Keep the P button and the dial simultaneously pressed
for about 3 seconds to reach the service/diagnostics
level. The display will show the symbols
the P button you will return to the basic display. You
can display the following functions / information:
Installation Manual recoVAIR/3 0020062918_03
275/3 350/3
0
0
-50
-50
+50
+50
275/3 350/3
0
0
-3
-3
+3
+3
275/3 350/3
0
0
0
0
31
31
275/3 350/3
01
01
01
01
12
12
275/3 350/3
2005
2005
2000
2000
2159
2159
. By pressing