Applicator Modes; Signals For Direct Dispense - Avery Dennison ALS 330 User Manual

Fully automatic labeller
Hide thumbs Also See for ALS 330:
Table of Contents

Advertisement

Operators Manual
ALS 330/430

8.2 Applicator modes

The machine is able to dispense the label direct on the passing product. There is also the
possibility to drive without any external control a wide range of applicators.
8.2.1

Signals for direct dispense

For direct dispensing the airstream signal can be used to control a pneumatic driven dispensing
edge. The start of the airstream signal (= motor run signal) could be behind the start of the
dispense motor, adjusted with the function APT3. The signal is switched inactive, when the
label dispense has been completed. Also the stop could be adjusted with the function ASTP to
switch inactive before or behind the dispense motor stop.
Ready
Product start
Label start
Suppression
Product start
Suppression
Dispense
Motor run
signal
1
Productstart disabled. PRDL activ
2
Missing Label: New start of dispense during dispenser activ
3
Inhibit activ
4
Machine not ready. Errorcondition or not online
Figure 17 Timing diagram direct dispense
Release 8/07
1
PRDL
POS
POS
APT3
Page 56
POS
2
ASTP
4
3
ASTP
Connections and signals