Avery Dennison ALS 330 User Manual page 35

Fully automatic labeller
Hide thumbs Also See for ALS 330:
Table of Contents

Advertisement

Operators Manual
ALS 330/430
Stop position ___________________________________________________ STOD
The stopping position (STOD) defines the position where the label stops after it has passed the
label sensor. The value represents 1/10 mm. In the example 0160 has to be adjusted by
pressing the FUNCTION keys. If an increased value is chosen, the label is advanced further, in
case of decreased values the position is closer to the label sensor.
Figure 16 Stop position
Dispense speed __________________________________________________VELO
The speed value VELO displays the dispensing speed in 0.1 m/min. The product conveyor
speed has to be constant to assure accurate labelling. A change of the product speed causes a
different position of the label on the product. In case of inaccurate labelling, it should be
verified, if the speed of the dispenser and your product match together. This is done
automatically if the optional automatic speed follower (APSF) is installed.
If the machine is equipped with an applicator, two parameters in the standard menu can be
changed. The delay time which specifies the moment when the applicator must put the label
onto the product and the blow time - how long the applying of the label should take.
Start delay_______________________________________________________STAD
By the aid of the parameter STAD the period of time between the recognition by the product
sensor and the dispensing of the label onto the product is determined. The time units are ms,
the time is adjusted by the keys FUNCTION.
Release 8/07
Page 33
Operation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents