Operators Manual
ALS 330/430
Dispenser stopped ________________________________________________ OFF
The dispenser function is stopped. Single labels could be dispensed with the FEED key.
Material initialisation _______________________________________________ INIT
A new initialisation of material is necessary. Pressing the FEED key will start the initialisation.
Label position ____________________________________________________POS
The position of the label can be changed by the parameter POS while the machine is in
operation. The display is presented in 1/10 mm and means the distance between product
sensor and labelling position of the product. The display value 0500 would mean 50.0 mm. By
pressing the key PRIOR the value is increased, i.e. the label is put on later. By pressing the key
NEXT FUNCTION the value is decreased and the label is put on earlier.
The labelling position is also changed by variation of the product speed. In this case first control
you product speed and the dispense speed VELO. Only if both speed matches adjust the
position with the POS function.
Figure 15 Label position