APPENDIX A
PATTON ELECTRONICS MODEL 1060

SPECIFICATIONS

Transmission Format:
Asynchronous
Transmission Line:
19 to 26 AWG twisted pair
Range:
(See table on page 14)
Serial Interface:
EIA RS-232 (CCITT V.24), DB-25 female
Twisted Pair Interface:
Terminal blocks, RJ-11 jack
Data Rates:
0 - 115,200 bps
Applications:
Point-to-point or multipoint
Indicators:
Tri-state for transmit data, receive data,
control in, control out; dual-state for power,
test
Diagnostics:
Local Analog Loopback (LAL), Remote
Analog Loopback (RAL)
Optical Isolation:
2500V RMS (minimum)
Surge Suppression:
Over-voltage protection for opto-Isolators
via Silicon Avalanche Diodes
Power Supply:
Wall mount, 9-12VAC, 200ma
Temperature Range:
0-60°C (32-140°F)
Altitude:
0-15,000 feet
Humidity:
5 to 95% noncondensing
Dimensions:
4.127"W x 1.52"H x 5.0"L
Weight:
13.2 oz. (without transformer)
13
APPENDIX B
PATTON ELECTRONICS MODEL 1060

CABLE RECOMMENDATIONS

The Patton Model 1060 is designed and tested to communicate
over twisted-pair cable with the following characteristics:
Wire Gauge
Capacitance
19 AWG
83nF/mi or 15.72 pF/ft.
22 AWG
83nF/mi or 15.72 pF/ft.
24 AWG
83nF/mi or 15.72 pF/ft.
Using the above characteristics as a baseline, we estimate the dis-
tance limitations for the Model 1060 to be as follows.
Model 1060 Distance Table in Miles (km)
Data
Rate
19 (.9mm) 22 (.5mm) 24 (.4mm)
115,200
1.8 (2.9)
57,600
2.5 (4.0)
38,400
3.7 (6.0)
19,200
4.17 (6.7)
9,600
5.41 (8.7)
4,800
7.05 (11.3) 3.8 (6.1)
2,400
11.5 (18.5) 7.0 (11.3) 4.83 (7.8)
1,200
14.0 (22.5) 8.5 (13.7) 5.68 (9.1)
To reduce the potential of difficulties in the field, we recommend
that the cable used to connect the Model 1060s have a capacitance of
no greater than 20pF/ft., and that the wire be no thinner than 26 AWG.
The Model 1060 is designed to withstand normal environmental noise
and conditions. However, other environmental factors too numerous to
discuss may affect proper operation. The distance table above should
be used as a general guideline only.
Resistance
.0163 /ft.
.0326 /ft.
.05165 /ft.
Wire Gauge
.75 (1.2)
.38 (.6)
1.3 (2.1)
.95 (1.5)
1.5 (2.4)
1.33 (2.1)
1.9 (3.1)
1.42 (2.3)
2.6 (4.2)
2.08 (3.3)
2.84 (4.6)