Download Print this page

Patton electronics 1002S User Manual

Asynchronous 2-wire / coax short range modem

Advertisement

Quick Links

USER
MANUAL
MODEL 1002
and 1002S
Asynchronous
2-Wire / Coax
Short Range Modem
Part #07M1002-C
Doc. #050011UC
Revised 4/28/98
An ISO-9001
Certified Company
SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007
http://www.patton.com

Advertisement

loading

Summary of Contents for Patton electronics 1002S

  • Page 1 USER MANUAL MODEL 1002 and 1002S Asynchronous 2-Wire / Coax Short Range Modem SALES OFFICE Part #07M1002-C Doc. #050011UC (301) 975-1000 Revised 4/28/98 TECHNICAL SUPPORT (301) 975-1007 An ISO-9001 http://www.patton.com Certified Company...
  • Page 2: Warranty Information

    1.0 WARRANTY INFORMATION Patton Electronics warrants all Model 1002 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification.
  • Page 3: General Information

    An additional enclosure option allows termination of coax cable via female BNC. The Model 1002S is a surge protected version of the Model 1002 that uses the latest in bi-directional, clamping, transient suppressors to protect itself and connected equipment against harmful transient discharges.
  • Page 4 Terminal Block Surge Suppressors (1002S only) Strip the outer insulation from the twisted pairs about one inch from the end. Strip back the insulation on each of the 2 wires about .25”. Insert the two wire data line to the center (signal) and shield (ground) terminal posts, then tighten the screws.
  • Page 5 Place the 2 halves of the strain relief assembly on either side of the telephone wire and press together very lightly. Slide the assembly until it is 2 inches from the terminal posts and press together firmly. Insert the strain relief assembly and connected wire into the slot in the bottom half of the modem case;...
  • Page 6 DSR and DCD turn “ON” immediately after the terminal raises DTR; CTS turns “ON” immediately after the terminal raises RTS Surge Protection: Compliant with IEC 801.5 level 2, 1kV (Model 1002S Only) Data Rate: 0 to 19.2 Kbps Range: 2.0 miles @ 0 to 9600 bps 5.0 miles @ 19,200 bps...
  • Page 7 APPENDIX B PATTON MODEL 1002 CABLE RECOMMENDATIONS The Patton Model 1002 operates at frequencies of 20kHz or less and has been performance tested by Patton technicians using twisted-pair cable with the following characteristics: Wire Gauge Capacitance 19 AWG/.9mm 83nf/mi or 15.72 pf/ft. 22 AWG/.6mm 83nf/mi or 15.72 pf/ft.
  • Page 8 APPENDIX D PATTON MODEL 1002 BLOCK DIAGRAM Copyright © 1998 Patton Electronics Company All Rights Reserved...

This manual is also suitable for:

1002