Patton electronics 1060 User Manual

User manual model 1060 ac powered, asynchronous short range modem
Hide thumbs Also See for 1060:

Advertisement

Quick Links

Dear Valued Customer,
Thank you for purchasing Patton Electronics products! We do
appreciate your business. I trust that you find this user manual helpful.
We manufacture one of the widest selections of data
communications products in the world including CSU/DSU's, network
termination units, powered and self-powered short range modems, fiber optic
modems, interface converters, baluns, electronic data switches, data-line surge
protectors, multiplexers, transceivers, hubs, print servers and much more. We
produce these products at our Gaithersburg, MD, USA, facility, and can
custom manufacture products for your unique needs.
We would like to hear from you. Please contact us in any of the
following ways to tell us how you like this product and how we can meet your
product needs today and in the future.
Web:
http://www.patton.com
Sales E-mail:
sales@patton.com
Support E-mail:
support@patton.com
Phone - Sales
(301) 975-1000
Phone - Support
(301) 975-1007
Fax:
(301) 869-9293
Mail:
Patton Electronics Company
7622 Rickenbacker Drive
Gaithersburg, MD 20879 USA
We are committed to a quality product at a quality price. Patton
Electronics is BABT and ISO 9001 certified. We meet and exceed the highest
standards in the industry (CE, UL, etc.).
It is our business to serve you. If you are not satisfied with any
aspect of this product or the service provided from Patton Electronics or its
distributors, please let us know.
Thank you.
Burton A.Patton
Vice President
P.S. Please tell us where you purchased this product.
_______________________________________________________________
_______________________________________________________________
_______________________________________________________________
_______________________________________________________________
_______________________________________________________________
_______________________________________________________________
_______________________________________________________________
USER
MANUAL
MODEL 1060
AC Powered, Asynchronous
Short Range Modem
Part #07M1060-C
Doc. #058011C
Revised 11/3/97
C E R T I F I E D
An ISO-9001
Certified Company
SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007
http://www.patton.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1060 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Patton electronics 1060

  • Page 1: User Manual

    P.S. Please tell us where you purchased this product. _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ USER MANUAL MODEL 1060 AC Powered, Asynchronous Short Range Modem Part #07M1060-C SALES OFFICE Doc. #058011C (301) 975-1000 Revised 11/3/97 TECHNICAL SUPPORT C E R T I F I E D...
  • Page 2: Warranty Information

    However, there is no guarantee that interference will not occur in a particular installation. If the Model 1060 does cause interference to radio or television reception, which can be...
  • Page 3 115.2 Kbps and extends RS-232 transmission distances up to 14 miles over two twisted pair. The Model 1060 is housed in a sturdy metal case and comes with either 115 or 220V external transformers. This is the top-of-the-line in asynchronous short range modems.
  • Page 4: Special Configuration

    Correct setting of the DCE/DTE switches eliminates the need for RS-232 crossover cables. If the RS-232 device you are connecting to the Model 1060 is a PC, terminal or host, or is wired like one, set both of the DCE/DTE switches to "DCE". If the RS-232 device you are connecting to the Model 1060 is a modem or multiplexer, or is wired like one, set both of the DCE/DTE switches to "DTE".
  • Page 5: Installation

    Be sure the end-to-end connections follow the diagram above. 4.1.2 TWISTED PAIR CONNECTION USING RJ-11 the RJ-11 jack in the back of the Model 1060 to make the connection. The RJ-11 jack on a Model 1060 series Short Range Modem is prewired for a standard TELCO wiring environment.
  • Page 6 4.3 RS-232 CONNECTION communications hardware, use a straight through RS-232 cable. Plug the cable directly into the DB-25 port on the rear of the Model 1060. The DCE/DTE switches eliminate the need for a crossover cable. Using a star topology, you may connect several Model 1060s...
  • Page 7 Once you have configured each Model 1060 properly and connected it, simply plug in the AC power adapter to get it running; there is no power switch on the Model 1060. You can monitor the operation of the Model 1060 using the front panel LED indicators and built-in loopback test modes.
  • Page 8 4.127"W x 1.52"H x 5.0"L Weight: 13.2 oz. (without transformer) APPENDIX B PATTON MODEL 1060 CABLE RECOMMENDATIONS The Patton Model 1060 is designed and tested to communicate over twisted-pair cable with the following characteristics: Wire Gauge Capacitance 19 AWG 83nF/mi or 15.72 pF/ft.
  • Page 9: Block Diagram

    4- (RTS) Request to Send 5- (CTS) Clear to Send 6- (DSR) Data Set Ready 7- (SG) Signal Ground From Model 1060 Data Term. Ready (DTR) - 20 8- (DCD) Data Carrier Detect DIRECTION To Model 1060 From Model 1060...
  • Page 10: Troubleshooting

    TROUBLESHOOTING SYMPTOM PROBLEM "TD" and "RD" LEDs 1. Improper RS-232 1. Check wiring indicate activity, but wiring between Model 1060 units will not and connected serial communicate or device—it should be data is garbled straight through 2. Improper twisted 2. Compare your...