Patton electronics 1060 User Manual

Ac powered, asynchronous short range modem
Hide thumbs Also See for 1060:

Advertisement

Quick Links

MODEL 1060
AC Powered, Asynchronous
Short Range Modem
Part #07M1060-D
Doc. #058011UD
Revised 08/12/99
An ISO-9001
Certified Company
SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007
http://www.patton.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1060 and is the answer not in the manual?

Questions and answers

Summary of Contents for Patton electronics 1060

  • Page 1 MODEL 1060 AC Powered, Asynchronous Short Range Modem Part #07M1060-D SALES OFFICE Doc. #058011UD (301) 975-1000 Revised 08/12/99 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com An ISO-9001 Certified Company...
  • Page 2: Warranty Information

    However, there is no guarantee that interfer- ence will not occur in a particular installation. If the Model 1060 does cause interference to radio or television reception, which can be deter-...
  • Page 3 In the majority of applications, you won't need an in-depth knowl- assignments. Data lines are protected from ground loops and electri- edge of the Model 1060's capabilities to get up and running. The fol- cally volatile environments by optical isolation and Silicon Avalanche lowing "quick set-up"...
  • Page 4: Special Configuration

    Control Output (C RS-232 crossover cables. If the RS-232 device you are connecting to the Model 1060 is a PC, terminal or host, or is wired like one, set both The Control Output signal is transmitted by the local Model 1060 of the DCE/DTE switches to "DCE".
  • Page 5: Installation

    If your two-pair cable is terminated in an RJ-11 plug, you may use one of two methods: terminal blocks or RJ-11 jack. Figure 2 (below) the RJ-11 jack in the back of the Model 1060 to make the connection. shows the location of the terminal blocks and RJ-11 jack, as well as The RJ-11 jack on a Model 1060 series Short Range Modem is the female DB-25, on the rear of the Model 1060.
  • Page 6 To connect the Model 1060 to a piece of data terminal or data communications hardware, use a straight through RS-232 cable. Plug the cable directly into the DB-25 port on the rear of the Model 1060. The DCE/DTE switches eliminate the need for a crossover cable.
  • Page 7: Operation

    AC power adapter to get it running; there is no The second test mode is the Remote Analog Loop. To enter this power switch on the Model 1060. You can monitor the operation of the mode, set one of the Model 1060s (local) in test mode by depressing Model 1060 using the front panel LED indicators and built-in loopback the “Loopback”...
  • Page 8: Specifications

    APPENDIX B PATTON ELECTRONICS MODEL 1060 PATTON ELECTRONICS MODEL 1060 SPECIFICATIONS CABLE RECOMMENDATIONS The Patton Model 1060 is designed and tested to communicate Transmission Format: Asynchronous over twisted-pair cable with the following characteristics: Transmission Line: 19 to 26 AWG twisted pair...
  • Page 9: Interface Pin Assignments

    5- (CTS) Clear to Send To Model 1060 6- (DSR) Data Set Ready To Model 1060 7- (SG) Signal Ground From Model 1060 Data Term. Ready (DTR) - 20 8- (DCD) Data Carrier Detect To Model 1060 From Model 1060...
  • Page 10 APPENDIX E APPENDIX E (continued) TROUBLESHOOTING PATTON ELECTRONICS MODEL 1060 TROUBLESHOOTING PATTON ELECTRONICS MODEL 1060 SYMPTOM PROBLEM SOLUTION SYMPTOM PROBLEM SOLUTION "TD" and "RD" LEDs 1. Improper RS-232 1. Check wiring LEDs do not light 1. Have another cup of 1.