Download Print this page

Radio Frequency Interference Statement; Specifications - Patton electronics 1000P User Manual

Non-powered short haul modem

Advertisement

RADIO FREQUENCY INTERFERENCE STATEMENT

This equipment generates, uses and can radiate radio frequency energy and if
not used in accordance with this manual, may cause interference to radio
communications. It has been tested and found to comply with the limits for a
Class A computing device pursuant to Subpart J of Part 15 of FCC rules,
which are designed to provide reasonable protection against such interference
when operated in a commercial environment. Operation of this equipment in a
residential area is likely to cause interference in which case the user at his own
expense be required to correct the interference.
If this unit is used on a DTE/DCE which requires use of shielded cables for
compliance with FCC Part 15, then use of a filtered-pin connector may be
required to maintain FCC compliance.

1.0 SPECIFICATIONS

Operating
Environment:
Dimensions:
Weight:
Power:
These units derive power from a terminal or computer. The following
signals must be available at the RS-232 connector:
DCE Configuration of the 1000P when connected to a DTE:
• The - and + voltage is taken from pins 2, 4, 9, and 20.
DTE Configuration of the 1000P when connected to a DCE:
• The - and + voltage is taken from pins 3, 5, 6, 8, or 9.
NOTE:
When power is removed from the DCE or DTE to which the Model
1000P is connected, the 1000P can no longer send a signal to the
remote receiver. Under this condition, the idled cable is susceptible
to noise reception. The remote receiver may output erroneous
data bits as a result of noise.
32 to 112 F (0 to 45 C), 0 to 95%
relative humidity
2.20" x 1.75" x .75"
Powered from RS-232C Connector
(+12V DTR/DSR), 6.3 mA)
1
Date Rates:
Transmission Format:
Transmission Mode:
Connectors - RS-232:
Connectors - Line:
Surge Protection:
Factory Switch Setting:
Cable Type:
19,200 bps (according to the RS-
232 interface)
Asynchronous
Full duplex
1000PM - DB-25 male
1000PMRJ11 - DB-25 male
1000PMRJ45 - DB-25 male
1000PF - DB-25 female
1000PFRJ11 - DB-25 female
1000PFRJ45 - DB-25 female
1000PM - strain relief
1000PMRJ11 - RJ11 (6 wire)
1000PMRJ45 - RJ45 (8 wire)
1000PF - strain relief
1000PFRJ11 - RJ11 (6 wire)
1000PFRJ45 - RJ45 (8 wire)
Compliant with IEC 801.5 level 2,
1kV (Model 222NS Only)
DCE; data is received from the
remote short range modem via
RX+ and RX-, and is sent to the
DTE from the Model 222N via pin 3
of the RS-232 interface; (the RS-
232 interface is the DB-25
connector closest to the DTE/DCE
switch).
4-wire, unloaded, customer-owned
twisted pair cable with DC continuity
2

Advertisement

loading