Station Loop Lengths - Toshiba Strata CIX40 General Description Manual

Hide thumbs Also See for Strata CIX40:
Table of Contents

Advertisement

Station Loop Lengths

In a single site installation, the Base and optional Expansion cabinets must be placed within the
allowed maximum distance of each other as designated by
Table 38
Station Loop Lengths
Mode
DP5000, DKT3000/3200 or DKT2000-series
DP with DOCA
DKT with BVSU or DVSU
DP with DOCA-1A
DKT with BHEU or HHEU
DKT with BPCI
DKT with BPCI + BHEU
DP with DOCA
DKT with BVSU + BHEU
4
or DVSU + HHEU
DP with DKM5020 or LM5110
DKT with DADM3020 or DADM2020 (1
2, 5
ADM)
DKT with DADM3020 or DADM2020 (2
2, 5
ADMs)
DDM5060 or DDSS3060, DDSS3060 or
DDSS2060
BATI, RATI
DDCB3
Standard telephones, voice mail, AA, etc.
IPT2010-SD
IPT2020-SD
IPT2008-SD
IPT1020-SD
1. When the system is powered by backup battery, range may be less as the backup battery is discharged.
2. One-pair wiring must be used with BWDKU and BDKS and CIX40 digital circuits (see
and BDKS and CIX40 digital circuits do not support two pair wiring.
3. Two-pair wiring or optional telephone power supply is required to achieve maximum range in all cases.
4. DP5000-series does not require BHEU for headset and does not support BPCI.
5. BDKS and BWDKU do not provide the power wire pair; an external power supply is required to achieve
maximum range (see "Digital Telephone DSS and DDCB External Power Connection" in Chapter 8 – MDF
circuit card Wiring of the
6. See manufacturer's product specifications for exact resistance of device.
Strata CIX General Description
1
Maximum line length (24 AWG)
1 Pair
1000 ft. (303m)
4
4
675 ft. (204m)
500 ft. (151m)
1000 ft. (303m)
Approx. 3000 ft.
(909 m) with 150
ohm device.
Approx. 9000 ft.
(2727 m) with 150
ohm device.
Approx. 21000 ft.
(6363 m) with 150
ohm device.
The IP telephone interface is 10Base-T/100Base-TX and requires
CAT5/5e/6 twisted pair cabling.
The maximum distance between the IP telephone jack and the
ethernet device it connects to is 100 meters (328 ft.). This includes
the 3 meter (9.84 ft.) straight-through CAT5 cable (black) supplied
with the IP telephone. Ethernet devices include
MIPU / LIPU / BIPU-M2A, BIPU-M1A servers, routers, etc.
Strata CIX I&M
Manual).
12/07
Table
38.
2 Pair (Not
2
Available for CIX40
or BDKS)
1000 ft. (303m)
1000 ft. (303m)
n/a
1000 ft. (303m)
6
n/a
6
6
Appendix — Specifications
Reserve Power
1 Pair plus
3
external power
1000 ft. (303m)
1000 ft. (303m)
n/a
1000 ft. (303m)
n/a
Figure
2). The BWDKU
169

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata cix100-sStrata cix200Strata cix100Strata cix670

Table of Contents