3rd PWR Supply PWR Fault

Detect (J3P)
The system can notify you in the event of
a power supply failure. This feature avail-
able when three power supply units are
installed in the chassis with one acting
as a backup. If you only have one or two
power supply units installed, you should
disable this (the default setting) with J3P
to prevent false alarms.

Audio Enable/Disable

JPAC enables or disables Audio Controller
on the motherboard. See the table on the
right for jumper settings. The default setting
is enabled.
LAN1/2
CD2 CD1
Line-In/
Line-
JPAC
Out
Mic
B
SIM LP IPMI
PCI-Exp x16
PCI-33MHz
Jumper Setting
Closed
Open
CPU
PSF
J17
A
Fan 1
J3P
JAR
SCSI CTRL
320 SCSI Channel B
2-27
Chapter 2: Installation
3rd PWR Supply PWR Fault
Jumper Settings
Defi nition
Enabled
Disabled (*Default)
Audio Enable(JPAC)
Jumper Settings
Jumper Setting
Defi nition
1-2
Enabled (Default)
2-3
Disabled
8-pin PWR
A. 3rd PWR Fail
B. Audio Enable