Thermo Scientific Orion Star User Manual page 19

Meter
Hide thumbs Also See for Orion Star:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Top Line
Middle Line
rEAd
tyPE
rEAd
tInE
L0g
dEL
L0g
AUt0
gEn
dEgC
gEn
StIr
gEn
PASS
gEn
AUt0
gLP
SEt
dAtE
H0Ur
dAtE
tInE
dAtE
tYPE
dAtE
YEAr
dAtE
dAtE
dAtE
dAY
r232
bAUd
r232
0UtF
AUt0
SAPL
AUt0
trAY
AUt0
rInb
AUt0
rSEC
AUt0
PH
AUt0
0rP
AUt0
ISE
1
AUt0
10
AUt0
100
AUt0
AUt0
C0nd
AUt0
n0SA
Thermo Scientific Orion Star
Bottom Line
AUt0, tImE, C0nt,
00:05 to 99:59
n0, YES
0FF, 0n
-5.0 to 105
0FF, 1, 2, 3, 4, 5, 6, 7
0000 to 9999
0n, 0FF
0FF, 0n
HH00 to HH23
mm00 to mm59
mdY, dmY
2000 to 2099
mm01 to mm12
dd01 to dd31
1200, 2400, 4800, 9600
Prnt, C0mP
0FF, 0n
28, 48
1, 2, 3, 4, 5
5 to 60
0, 1, 2, 3
n0, YES
0, 2, 3
ISE1
ISE2
ISE3
0, 1, 2, 3
0 to 47
and Star Plus Meter User Guide
Setup Menu Description (default setting, method specific)
Measurement read type as AUTO-READ, timed or continuous
(AUt0, yes)
Timed measurement value in minutes and seconds (01:00, yes)
Note: This submenu is only available when the timed
measurement read type is selected.
Delete datalog after download option, select YES to delete the
datalog when it is downloaded or select nO to overwrite the oldest
data when the datalog is full and not delete the datalog when
it is downloaded (n0, yes)
Automatic datalog point saving option (0FF, yes)
Manual temperature value (25.0, yes)
Stirrer speed – 3, 4 and 5 Star benchtop meters only (4, yes)
Meter password entry (0000, yes)
Automatic meter shutoff option (0n, no)
GLP option, GLP feature enables or disables methods (0FF, no)
Hour setting (HH12, no)
Minute setting (mm00, no)
Date format as month, day, year or day, month, year (mdY, no)
Year setting (2004, no)
Month setting (mm01, no)
Day of the month setting (dd01, no)
Baud rate setting (9600, no)
Output format for printer or computer, COmP format is comma
delimited (Prnt, no)
Autosampler – 3, 4 and 5 Star Plus benchtop meters only (OFF, no)
Beaker tray setting (28, no)
Number of rinse beakers (3, no)
Rinse time in each rinse beaker, seconds (10, no)
pH calibration points (3, no)
ORP calibration option, appears if 0 was selected for PH (n0, no)
ISE calibration points, appears if 0 was selected for PH (2, no)
Concentration value of ISE standard 1, appears if 2 or 3 was
selected for the ISE calibration points (1, no)
Concentration value of ISE standard 1, appears if 2 or 3 was
selected for the ISE calibration points (10, no)
Concentration value of ISE standard 1, appears if 3 was selected
for the ISE calibration points (100, no)
Conductivity calibration points (3, no)
Number of sample beakers (1, no)
Meter Setup
EN-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents