5. Wipe lid, wheel, baffle, inside of storage area and dispense chute with damp cloth wrung out in Solution A.
6. Rinse all above items with damp cloth and wring out in clear water.
Note: To avoid possible damage to motor assembly, use a damp cloth only to clean storage hopper. Do not
allow water to run through center hole in bottom of hopper.
7.
Sanitize all above items with damp cloth wrung out in Solution B. Do not rinse.
8. Pour 284ml (1 cup) household bleach into drain pan, followed by 3.8L (1 gallon) hot tap water to flush drains.
9. Reinstall all parts.
Dispenser grille and drain pan – weekly intervals
1. Remove grille and wash with Solution A. Rinse thoroughly.
2. Pour 282ml (1 cup) household bleach into drain pan, followed by 3.8L (1 gallon) of hot tap water to flush
drains.
Splash panel front, SensorSAFE dispensers
1. Deactivate dispensing by pressing and releasing clean switch located on left side of unit under top front
cover.
2. Clean lens using a soft cloth and mild, non-abrasive, non-chlorine based cleaner.
3. Reactivate dispensing by pressing and releasing clean switch again.
Icemaker cleaning & sanitizing
Preventive maintenance
Periodic cleaning of Follett's icemaker system is required to ensure peak performance and delivery of clean,
sanitary ice. The recommended cleaning procedures which follow should be performed at least as frequently as
recommended below and more often if environmental conditions dictate.
Cleaning of the condenser can usually be performed by facility personnel. Cleaning of the icemaker system
in most cases should be performed by your facility's maintenance staff or a Follett authorized service agent.
Regardless of who performs the cleaning, it is the operator's responsibility to see that this cleaning is performed
according to the schedule below. Service problems resulting from lack of preventive maintenance will not be
covered under the Follett warranty.
Cleaning procedures
Recommended monthly cleaning of condenser
1. Use a vacuum cleaner or stiff brush to carefully clean condenser coils of air-cooled icemakers to ensure
optimal performance.
2. When reinstalling counter panels in front of remote icemakers, be sure that ventilation louvers line up with
condenser air duct.
Recommended semi-annual cleaning of icemaking system
Icemaking system can be cleaned in place without disassembling water system. Cleaning should be performed at
least every 6 months, and more often if local water conditions dictate.
1. Disconnect power to icemaker.
2. Remove any icemaker panels required to gain access to water reservoir and electrical control box.
3. Turn compressor switch on electrical box of icemaker to OFF position.
4. Remove water reservoir cover and block up reservoir float or close water supply valve.
5. Drain water from reservoir by releasing evaporator drain line from float reservoir bracket and removing plug
from drain line.
11