Dispenser Troubleshooting - Lever Models - Follett C/E12CI400A Installation, Operation & Service Manual

12 series - 220v 60hz/230v 50hz ice and water dispensers
Table of Contents

Advertisement

Ice capacity test
Icemaker production capacity can only be determined by weighing ice produced in a specific time period.
1. Remove top panel and hopper lid of unit.
2. Weigh and record weight of container used to catch ice.
3. Run icemaker for at least 15 minutes.
4. Catch ice for 15 or 20 minutes.
5. Weigh harvested ice and record total weight.
6. Subtract weight of container from total weight.
7. Convert fractions of pounds to decimal equivalents (Ex. 6 lbs 8 oz = 6.5 lbs).
8. Calculate production using following formula:
1440 min. x wt. of ice produced
Total test time in minutes
9. Calculated amount per 24 hours should be checked against rated capacity for same ambient and water
temperatures in Ice Production Table (see page 22).
Dispenser troubleshooting
Disconnect power to unit before putting hands or arms in storage area or attempting any
!
repair or service to equipment.
Before calling for service:
Check that no ice is in the dispenser bin area
Check that congealed ice is not causing a jam
Troubleshooting the dispenser – lever models
Problem
Does not dispense ice.
Dispense wheel rotates
continuously.
Icemaker runs continuously.
Does not dispense water.
=
Indicators
1. Power switch off or faulty.
2. Faulty dispense switch.
3. Wheel motor malfunction.
4. Storage hopper cover
(inside dispenser cabinet)
off or ajar.
1. Dispense switch contacts
burned shut.
1. Faulty or incorrectly
positioned bin stat.
1. Faulty water solenoid valve.
2. Faulty dispense switch.
3. Power switch off or faulty.
24
Production capacity/24 hr. period
Check that all switches and circuit breakers are on
Check that all drains are clear
1. Check switch – turn on or replace if faulty.
2. Replace switch.
3. Check motor and capacitor and replace
as required.
4. Secure cover.
1. Replace dispense switch.
1. Check for proper positing – if stat does
not open when ice is places on capillary
tube, replace stat.
1. Replace water solenoid valve.
2. Replace dispense switch.
3. Check switch – turn on or replace
if faulty.
Corrective action