Agilent Technologies Series N6700 User Manual page 17

Low-profile modular power system
Hide thumbs Also See for Series N6700:
Table of Contents

Advertisement

SCPI Command
FETCh[:SCALar] (continued)
:POWer
[:DC]? (@chanlist)
:VOLTage
[:DC]? (@chanlist)
:ACDC? (@chanlist)
:HIGH? (@chanlist)
:LOW? (@chanlist)
:MAXimum? (@chanlist)
:MINimum? (@chanlist)
:ARRay
:CURRent [:DC]? (@chanlist)
:POWer [:DC]? (@chanlist)
:VOLTage [:DC]? (@chanlist)
:ELOG <NR1>, (@chanlist)
FORMat
[:DATA] ASCII | REAL
:BORDer NORMal | SWAPped
INITiate
[:IMMediate]
:ACQuire (@chanlist)
:ELOG (@chanlist)
:TRANsient (@chanlist)
:CONTinuous
:TRANsient <Bool>, (@chanlist)
MEASure
[:SCALar]
:CURRent
[:DC]? (@chanlist)
:ACDC? (@chanlist)
:HIGH? (@chanlist)
:LOW? (@chanlist)
:MAXimum? (@chanlist)
:MINimum? (@chanlist)
:POWer
[:DC]? (@chanlist)
:VOLTage
[:DC]? (@chanlist)
:ACDC? (@chanlist)
:HIGH? (@chanlist)
:LOW? (@chanlist)
:MAXimum? (@chanlist)
:MINimum? (@chanlist)
:ARRay
:CURRent [:DC]? (@chanlist)
:POWer [:DC]? (@chanlist)
:VOLTage [:DC]? (@chanlist)
Series N6700 User's Guide
Description
Returns the average output power
Returns the average voltage
Returns the total rms voltage (AC + DC)
Returns the high level of a voltage pulse
Returns the low level of a voltage pulse
Returns the maximum voltage
Returns the minimum voltage
Returns the instantaneous output current
Returns the instantaneous output power
Returns the instantaneous output voltage
Returns the most recent external data log records
Returns data as ASCII or binary
Sets the byte order of the external data log data
(Acquire command only on N676xA, N678xA SMU and Option 054)
Enables the measurement system to receive triggers
Enables external data log measurements
Enables the output transient system to receive triggers
Enables/disables continuous transient triggers
Takes a measurement; returns the average current
Takes a measurement; returns the total rms current (AC + DC)
Takes a measurement; returns the high level of a current pulse
Takes a measurement; returns the low level of a current pulse
Takes a measurement, returns the maximum current
Takes a measurement, returns the minimum current
Takes a measurement, returns the average output power
Takes a measurement; returns the average voltage
Takes a measurement; returns the total rms voltage (AC + DC)
Takes a measurement; returns the high level of a voltage pulse
Takes a measurement; returns the low level of a voltage pulse
Takes a measurement, returns the maximum voltage
Takes a measurement, returns the minimum voltage
(Array commands only on N676xA, N678xA SMU and Option 054)
Takes a measurement; returns the instantaneous output current
Takes a measurement; returns the instantaneous output power
Takes a measurement; returns the instantaneous output voltage
Quick Reference 1
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents