Agilent Technologies Series N6700 User Manual page 10

Low-profile modular power system
Hide thumbs Also See for Series N6700:
Table of Contents

Advertisement

1 Quick Reference
Model Differences
Feature
(● = available)
50 W output rating
100 W output rating
300 W output rating
500 W output rating
Output disconnect relays
Output disconnect/polarity reversal relays
Autoranging output capability
Voltage or current turn-on priority
Precision voltage and current measurements
Low voltage and current output ranges
Low voltage and current measurement ranges
200 microampere measurement range
Simultaneous voltage and current measurements
Output list capability (
Test Extensions
Array readback capability (
Test Extensions
Programmable sample rate (
Test Extensions
Double-wide (occupies 2 channel locations)
Feature
(● = available)
Output rating
2-quadrant operation
4-quadrant operation
Auxiliary voltage measurement input
Output disconnect relays
Negative voltage protection
Voltage or current priority mode
Programmable output resistance
600 mV output range
300 mA output range
100 mA, 10 mA output ranges
1 V, 100 mV measurement ranges
100 mA, 1 mA, 10 μA measurement ranges
150 mA measurement range
Simultaneous voltage and current measurements
Seamless measurement autoranging
Output list capability
NOTE 3, 4
Array readback capability
NOTE 3
Programmable sample rate
NOTE 3
10
DC Power
N673xB, N674xB, N677xA
N6731B – N6736B
N6741B – N6746B
N6773A – N6777A
Option 761
Option 760
NOTE 1
NOTE 2
)
Option 054
NOTE 3
)
Option 054
NOTE 3
)
Option 054
NOTE 3
Source/Measure Units (SMU)
N6781A
20 W
1
Output current is limited to 10A max. on Models N6742B and N6773A with Option 760.
Option 760 is not available on Models N6741B, N6751A, N6752A, N6761A, and N6762A.
2
Option 2UA.is only available on Models N6761A and N6762A. It includes Option 761.
3
Only available when using the remote interfaces; not from the front panel.
4
List capability is not available on the negative current output on Model N6783A
High-Performance
N675xA
N6751A
N6752A
N6753A, N6754A
N6755A, N6756A
Option 761
Option 760
Option 054
Option 054
Option 054
N6753A – N6756A
N6782A
N6784A
20 W
20 W
Precision
N676xA
N6761A
N6762A
N6763A, N6764A
N6765A, N6766A
Option 761
Option 760
N6761A, N6762A
N6761A, N6762A
Option 2UA
N6763A – N6766A
Application-Specific
N6783A-BAT
N6783A-MFG
24 W
18 W
Option 761
Option 761
Series N6700 User's Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents