Test the Remaining Pods in 250 Mb/s Mode

Set up the second E5383A Flying Lead Probe Set

Test the remaining pods

16800 Series Portable Logic Analyzers Service Guide
The logic analyzer master card's Pod 1 clock ("Clk1" in the
Sampling setup dialog) is used for testing all Pods above 4 in
the 250 Mb/s mode. Therefore, two E5383A Flying Lead
Probe Sets are required to test the remaining pods.
1
Disconnect the first E5383A Flying Lead Probe Set from
the pod it is currently connected to (Pod 4) and connect
it to the pod under test (Pod 5).
2
Remove the pod under test Flying Lead Probe Set's CLK
lead from the SMA/Flying Lead test connectors. (Do not
remove the channel 2, 6, 10, and 14 leads from the
SMA/Flying Lead test connectors.)
Connect a second E5383A Flying Lead Probe Set to Pod 1
3
of the logic analyzer's master card.
Connect the Pod 1 Flying Lead Probe Set's CLK lead to
4
the SMA/Flying Lead test connector's pin strip connector
at the 8133A pulse generator's Channel 1 OUTPUT.
Perform the normal and complement tests for each
1
remaining pod on the logic analyzer, changing the
connection to the pod, channel assignments, thresholds,
etc. as appropriate.
Test using the logic analyzer master card's Pod 1 clock,
"Clk1", for all Pods above 4.
Upon completion, the logic analyzer is completely tested
in the 250 Mb/s mode.
3
Testing Performance
59