WI742C 08/00
Disarming
When the exit time has elapsed, the display will read "SYSTEM ARMED". This indicates that upon entering the premises
through an exit/entry door, there will be an entry delay to allow time to disarm the panel. The GEM-RP1CAe2 display will
read "ENTRY TIME XXX" ("XXX" representing the programmed entry-delay time, in seconds). The sounder will come on and the
entry delay will immediately start counting down toward "000" in intervals of 10 seconds, indicating the available time
remaining to disarm the panel. The sounder will pulse during the final 10 seconds.
!
To disarm the panel, enter a valid User Code, then press the
Arming with No Delay
!
Press the
button prior to or after arming.
F
This feature allows normal exit delay, but cancels the next entry delay through an entry/exit zone. The display red LED will
flicker. This feature may be used to provide instant protection while you or someone else is still on the premises. It will be
canceled automatically upon disarming.
Priority Arming
A 2-second tone and "ZONE NOT NORMAL/CAN'T ARM" displayed when attempting to arm indicates a priority condition; that is, a
problem exists on at least one zone that has been designated a Priority Zone, or a system trouble exists. The trouble(s)
must be corrected before the panel can be armed. The display will read "ZONE FAULTS", then automatically scroll through all
unsecured zones. If a system trouble is indicated, display the system trouble.

Area Arming/Overview Mode

In a partitioned system, either or both secured areas may be armed (or disarmed) simultaneously from either the Overview
Mode or the Manager's Mode (if enabled). To arm or disarm the alternate area, see Keypad Area Change, which follows.
Overview Mode
To enable or disable Overview, see ACTIVATE OVERVIEW function later in this section. The Overview Mode is a high
security mode of operation requiring a Level-3 User Code with Overview Option, wherein the status of both areas is
displayed at the keypad. When arming, the "home" area remains disarmed. To arm the alternate area, see Keypad Area
Change, which follows.
In the Overview Mode, "OV(-)" will be displayed, where each dash ("-") represents an area. In programmed areas, the dash
will be replaced by one of the following:
!
In the Overview Mode, the alternate ready area may be armed by pressing the
Note: The User Code must be valid in that area.
!
Similarly, the alternate armed area ("A") may be disarmed by pressing the
If any zone is not secured, the system will not arm and the keypad will display "CAN'T ARM SYSTEM / AREA # IN TROUBLE", where
"#" represents the area number.
Manager's Mode
The Manager's Mode, in contrast to the Overview Mode, is a low-security mode of operation.
!
Unlike the Overview Mode, when arming both areas press
"home" area will also arm.
As in Overview, if any zone is not secured, the area will not arm and the keypad will display "CAN'T ARM SYSTEM / AREA # IN
TROUBLE", where "#" represents the area number.
!
To disarm both areas, press
!
To arm the alternate area, see Keypad Area Change.
L
NAPCO Security Systems
"A" = Area Armed
"B" = Burglary Zone in Alarm
"C" = Check Trouble; Area in Function-Display Mode
"F" = Fire Zone in Alarm
"R" = Area Ready (no faulted zones)
"T" = Fire Trouble
"Z" = Zone Fault
and enter a valid user code.
0 G
J
button.
9 G
0 G
and enter a valid user code, the
9 G
X
GEM-P9600 Installation Instructions
!
Page 23
buttons.
buttons.