Testing The System - Gemini GEM-P9600 Installation Instructions Manual

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P9600:
Table of Contents

Advertisement

!
Page 12

TESTING THE SYSTEM

After installation is completed, test the system as follows.
!
1. Call the central station to inform them of the test.
!
2. Initiate an alarm, preferably on a zone that activates a steady siren, and verify proper signaling.
!
3. Wait 5 minutes.
!
4. Call the central station to confirm their receipt of a good transmission.
Note: Be sure to test all enabled keypad panics.
Signal Strength Testing/Wireless Systems
To test the operation of wireless transmitters, proceed as follows. (Note: Wireless systems have not been investigated by
UL.)
!
Fault a point of each transmitter to be tested by faulting the zone.
The transmitter signal strength can be displayed using the DISPLAY RF XMITTER STAT function. Enter a Level 3 User
Code or enter the Dealer Code, press the
YES (
button) and the Wireless Signal Strength of the wireless zone will be displayed. The Wireless Signal
E
Strength will be displayed from 1 to 10 with 10 being the strongest signal and any signal under 3 as unacceptable. Except
in the Fault-Find Mode, signal strengths less than 3 will be entered into the system log. Press NEXT (
step the next zone.
The last received signal strength for each transmission is always stored in memory and can viewed at any time using this
procedure. Signal strength can also be viewed through the PCD3000 Status Screen.
X
GEM-P9600 Installation Instructions
button and answer NO until "DISPLAY RF XMITTER STAT" is displayed. Press
A
WI742C 08/00
E
L
NAPCO Security Systems
button) to