Wiring Connections; Battery; Transformer; Siren/Bell Output - Gemini GEM-P9600 Installation Instructions Manual

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P9600:
Table of Contents

Advertisement

WI742C 08/00

WIRING CONNECTIONS

BATTERY

4 AH, 6 AH OR 7 AH
RECHARGEABLE
BATTERY 12 VDC

TRANSFORMER

AC IN, 16.5V/60HZ VIA
TRF11 OR TRF14
CLASS 2 TRANSFORMER
DO NOT CONNECT TO
SWITCHED OUTLET
SIREN/BELL BURG/FIRE ALARM OUTPUT
Connect the alarm sounding devices (self-contained sirens, speakers or a mechanical bells) to
terminals 5 (+) and 14 (-). Any self-contained siren requiring a 12 VDC input can be connected.
When connecting a mechanical bell, it must be supervised using a 2.2k Ohm resistor. To
connect 8 Ohm Speakers use a Siren Driver with the proper polarity observed. NOTE: Refer to
the Wiring Diagram for alarm current specification, bell supervision and burglary output relay.

AUXILIARY ALARM OUTPUT

Auxiliary Output can be activated depending on the programming options selected (see
GEM-P9600 Programming Instructions). Connect the device controlled by the programmable
output between terminal 8 (+) and terminal 14 (-). A programming option "Aux. Output Chirp on
Key-fob Arming" is available. If selected, an external siren driver can be connected to these
terminals.
L
NAPCO Security Systems
Connect a 16.5 VAC Transformer to Terminals 1 and 2, using a wire of #18 AWG. or
1
less at a distance of 15 ft. or less from the control panel. NOTE: Do not connect to a
switched outlet.
2
The RED (+) and BLACK (-) flying leads must be connected to
a 12VDC 4, 6 or 7 AH Rechargeable Battery, to serve as
backup power in the event of AC Power Failure. NOTE: To
calculate the available standby time refer to the Standby-
Battery Calculation Worksheet at the back of this manual.
X
GEM-P9600 Installation Instructions
!
Page 13