54
NOTE
If
Fan Status
fan status LED is amber while the power supply status LED is green, then this means a fan
inside the power supply is bad.
To view specific power supply status, move the cursor to Power Supply and press
The screen displays:
Supply #1: status <Absent, Okay, or FAIL>
Supply #2: status <Absent, Okay, or FAIL>
To view specific power supply information, press
Supply #X: status line. Supply #1 is the left power supply, when viewed from the back of
the system. The following information displays for the selected power supply:
AC: status (Absent, Ok, or FAIL)
DC: status (Off, Absent, Ok, or FAIL)
Fan #1: speed
Fan #2: speed
If the AC or DC status reports a failure, but the fans are still working, do not remove the
power supply. Remove the failed power supply only when the replacement power supply is
available for installation.
Fan #1 and Fan #2 show the status of the fans inside the power supply. When the status
is Ok, the fan speed is adequate to provide cooling. The normal speed for each fan is
3600 RPM (± 240 RPM). If the speed decreases below 2640 RPM, the status BAD displays.
Replace the power supply is one of its fans reports BAD, or shows a continual decline in fan
speed.
System with Single 300 Watt Power Supply
Path: System Status > Power Supply
Power Supply: status displays Okay or FAIL. If FAIL displays, the power supply should
be replaced.
To view specific power supply status, move the cursor to Power Supply and press
The screen displays:
DC: status <Ok, or BAD>
WARNING Power off the system immediately if a power supply shows a
Customer Response Center at 1-800-633-7248 to report the failure.
shows a failure and the
status (Off, Ok, or BAD)
status (Off, Ok, or BAD)
Power Supply Status
when the cursor is by either
ENTER
shows a failure, and the
ENTER
ENTER
status. Call the
BAD
.
.