Basic Functions (Fncf) - A&D AD-4410 Instruction Manual

Weighing indicator
Table of Contents

Advertisement

8.3. Basic Functions (fncf)

Function No.
Parameter
range
fncf01
F
000000
to
111111
fncf02
0
6
to
fncf03
1
3
to
fncf04
0
13
to
fncf05
0
16
to
Function
Each digit of the setting corresponds to a
key switch. Only available in the weighing
mode.
0: Does not disable the key switch function.
Disable key
1: Disables the key switch function.
switch
Key assignment to each binary digit
6
ZERO
Assigns a function to the F key.
0: None
1: Manual print command
2: Hold
3: Alternate switch
F key
4: Momentary switch
5: Clear the tare weight
6: Clear the zero value
NOTE: Clearing the zero value can be
1: 20 times/second
Display
2: 10 times/second
update rate
3: 5 times/second
Assigns a function to the
0: None
1: Zero tracking in progress
2: Alarm (Zero range setting error, over)
3: F key status
4: Near zero
5: HI output (Over the upper limit value)
6: OK output (Within upper and lower limit
display
7: LO output (Below the lower limit value)
8: User input 1
9: User input 2
10: User input 3
11: User output 1
12: User output 2
13: User output 3
Selects a cutoff frequency.
0: None
1: 11.0 Hz
2: 8.0 Hz
Digital filter
3: 5.6 Hz
4: 4.0 Hz
5: 2.8 Hz
6: 2.0 Hz
Page 43
Description
th
th
th
5
4
Net/B/G
TARE
NET GROSS
enabled or disabled by
values)
rd
nd
st
3
2
1
ON/OFF
ENTER
ESC
Calf15
display.
Default
value
000000
(binary)
0
1
0
8
AD-4410

Advertisement

Table of Contents
loading

Table of Contents