Weighing indicator
Table of Contents

Advertisement

Terminal No.
1
EXC+
2
SEN+
3
SEN-
4
EXC-
5
SIG+
6
SIG-
7
SHIELD
Load cell
EXC+
SIG-
EXC-
(A) 6-wire configuration connection to load cell (recommended)
EXC+
SIG-
EXC-
(B) 4-wire configuration connection to load cell (not recommended)
AD-4410
Load cell excitation voltage (+)
Sensing input (+)
Sensing input (-)
Load cell excitation voltage (-)
Load cell input (+)
Load cell input (-)
Shield
SIG+
Load cell
SIG+
Fig.4 Load cell connection configuration
Function
Load cell cable
EXC+
SEN+
SIG+
SEN-
EXC-
SHIELD
Load cell cable
EXC+
EXC-
SHIELD
Page 14
Indicator's load cell
connector
1
2
4
3
5
6
7
SIG-
Indicator's load cell
connector
SEN+
1
2
4
3
5
SEN-
6
7
SIG-
SIG+