Info Cid Numdrives; Info Cid Unitstatus; Info Cid Allunitstatus - 3Ware 720-0127-02 Manual

9000 series serial ata raid controller
Table of Contents

Advertisement

Chapter 3. Legacy CLI Syntax Reference
cid
info
numdrives
This command reports the number of drives currently managed by the
specified controller cid. This report does not include units that have been
removed (placed off-line) with the maint remove command.
Also note that a physically removed disk is not detected unless I/O is
performed against the disk. See "info cid pid smart" on page 94 for a
workaround.
Example:
//localhost> info c0 numdrives
/c0 Number of Drives = 5
cid
info
unitstatus
This command presents status of units managed by the specified controller
cid. It provides a list of units, their types, current status, percent complete if
rebuilding or verifying, size in GB, and the number of blocks of 512 bytes.
Example:
//localhost> info c0 unitstatus
Unit UnitType Status %Cmpl Stripe Size(GB)Cache AVerify OvrECC
----------------------------------------------------------
u0
cid
info
allunitstatus
This command presents a count of Total and NotOptimal units managed by
the specified controller cid. See "Info Commands" on page 85 for more
information on NotOptimal.
Example:
//localhost> info c0 allunitstatus
Total Units = 2
NotOptimal Units = 0
90
RAID-5 VERIFYING
79
3ware 9000 Series Serial ATA Controller CLI Guide
16K
819.446
ON
OFF
ON