[Maint] Rebuild Cid Uid Pid_List [Ignoreecc]; [Maint] Rebuild Cid Uid Pause - 3Ware 720-0127-02 Manual

9000 series serial ata raid controller
Table of Contents

Advertisement

Examples:
To create a 12-member RAID-0 array with 128K stripe size on controller 0:
CLI> maint createunit c0 rraid0 k256 p0-11
To create a hot spare using a drive on port-2 controller-0 for automatic
rebuilds:
CLI> maint createunit c0 rspare p2
[maint] rebuild
This command allows you to rebuild a DEGRADED unit by using the
specified port. Rebuild applies only to redundant arrays such as RAID 1,
RAID 5, RAID 10 and RAID 50.
During rebuild, bad sectors on the source disk cause the rebuild to fail. Using
the ignoreECC option (equivalent to checking the 'Force continue on source
errors' box in 3DM) allows the rebuild to continue when source errors occur,
but a file system check is recommended once the rebuild is complete.
Note: The ignoreECC option is not required for the 9000 series, if the variable
is already assigned when you create or set later. Refer to the "set
overwriteECC cid uid on|off" on page 112 for more info.
The rebuild process is a background process and changes the state of a unit to
REBUILDING. Various info commands also show a percent completion as
rebuilding progresses.
Ports that are to be used to rebuild a unit must be a Spare type or an
unconfigured drive. You must first use
then use
[maint] rebuild
This command allows you to pause the rebuild operation on the specified unit.
This feature is intended for model 7000 and 8000 only. Model 9000 has an on-
board scheduler where rebuild operations can be scheduled to take place at
specified start and stop times. Rebuild pause and resume function is provided
to enable 7000/8000 users to achieve similar functionality with the use of OS-
provided schedulers.
See also "Sched Commands" on page 104.
www.3ware.com
Alert!
When creating a hot spare, be sure to select a drive with an equal
or larger size than the smallest drive in your redundant array.
Otherwise it can't be used in a rebuild.
cid uid pid_list
to add the new drive before you can use
rescan
cid uid
pause
[ignoreECC]
to remove the failed drive,
remove
rebuild
Maint Commands
.
101

Advertisement

Table of Contents
loading

This manual is also suitable for:

9500s9550sx

Table of Contents