Adjusting The Contrast Of The Operation Panel Display; Production Control Switch Connecting Connector - JUKI DLU-5494N-7 Instruction Manual

1-needle, bottom­ and variable top feed lockstitch ­machine with automatic thread trimmer
Hide thumbs Also See for DLU-5494N-7:
Table of Contents

Advertisement

(2) Adjusting the contrast of the operation panel display

2
A

(3) Production control switch connecting connector

3
2
A
Light
Shade
3
1
1
–­6­–
)­ Press­ in­ the­ direction­ of­ arrow­ mark­ the­ click­ of­
section­ A ­ of­ cord­ outlet­ cover­ 2 ­ assembled­ in­
the­ rear­ of­ operation­ panel­ 1 ­ and­ remove­ the­
cover.
2)­ Turn­ LCD­ screen­ display­ brightness­ adjustment­
variable­ resistor­ 3 ­ to­ adjust­ the­ brightness­
(contrast)­of­LCD­screen.
1. To prevent the operation panel from
breakage, do not touch the circuit
board pattern and the connector
terminal.
2. Do not disassemble the operation
panel to prevent it from breakage.
)­ Press­ in­ the­ direction­ of­ arrow­ mark­ the­ click­ of­
section­ A ­ of­ cord­ outlet­ cover­ 2 ­ assembled­ in­
the­ rear­ of­ operation­ panel­ 1 ­ and­ remove­ the­
cover.
2)­ Connect­ the­ optional­ relay­ cable­ connector­
to­ CN05­ 3 ­ of­ the­ production­ control­ switch­
connecting­connector.
Prepare the switch main unit by the
customers or ask JUKI business office
about it.
Optional relay cable A (asm.)
JUKI Part No. 40008168
3 2 1
CN105

+5V
2
SW
3
GND

Hide quick links: