Changing the Presser Foot
CAUTION:
Turn OFF the power switch before changing the foot.
2
Always use the proper foot for the selected pattern. Wrong
foot can cause the needle to break.
3
To snap off:
Raise the needle and presser foot.
Press the red button on the back of the foot holder and the
1
foot will drop.
1 Red Button
2 Foot Holder
3 Presser Foot
To snap on:
Place the presser foot so the pin on the foot lies just under
the groove of the foot holder.
Lower the foot holder to lock the foot in place.
5
Each foot is marked with a letter for identification.
4
4 Groove
5 Pin
6 Identification Letter
6
Detaching and Attaching the Foot Holder
WARNING:
2
Turn OFF the power switch before detaching or attaching
the foot holder.
To detach:
Raise the presser bar and turn the thumbscrew
counterclockwise to remove the foot holder.
1
1 Thumbscrew
2 Foot holder
To attach:
Align the hole in the foot holder with the threaded hole in
3
the presser bar and insert the thumbscrew through the
hole.
Tighten the thumbscrew by turning it clockwise.
2
3 Presser Bar
1
9