TROUBLESHOOTING

4. TROUBLESHOOTING

4.1. POWER FAILURE

If electric power is removed for any reason, the appliance will shut down.
Wait five minutes after the power is restored before attempting to restart the appliance. This will allow
time for any gas that may have accumulated in the burner or tubes to dissipate.
To restart the appliance, follow the appliance start up procedure in section 2.2.
DO NOT attempt to operate this appliance during a power outage.

4.2. HIGH TEMPERATURE LIMIT

This appliance is equipped with a high temperature limit switch. The high temperature limit switch will
stop the appliance from functioning if the internal cook tank reaches an unsafe temperature. In the
event that the high temperature limit has tripped, Please refer to the following procedure to reset the
switch.
a. Turn the appliance off.
b. Allow the appliance ample time to cool to room
temperature.
c. Add oil/shortening to the cook tank as needed.
d. Press the high temperature reset button if equipped.
e. The high limit switch is now reset and the appliance is
ready for start up.
DO NOT add oil/shortening to the tank until it has been given ample time to cool down.
Failure to do so may result in damage to the appliance and/or injury to the operator.

4.3. DRAIN VALVE INTERLOCK

If your appliance is equipped with a drain valve interlock circuit, the appliance will stop heating if the
tank drain valve is opened. If your appliance is equipped with a float switch, the appliance will stop
heating if the oil/shortening level reaches an unsafe height. In some cases the appliance will turn off.
Refer to the following procedure to resume operation after the drain valve interlock is tripped.
1. Turn the appliance OFF (if not already OFF).
2. Close the tank drain valve and fill the tank with oil/shortening.
3. Turn the appliance ON.
24
CAUTION
WARNING
L20-332, rev. 1 (05/11)
High Temperature Reset Button