Junction Box Installation - Heat & Glo LUX60 Owner's Manual

Table of Contents

Advertisement

C. Junction Box Installation
If the box is being wired from the OUTSIDE of the appli-
ance:
Remove the cover plate located on the outer shell - right
side (see Figure 13.2).
Install the supplied Romex™ connector in the cover
plate.
Feed the necessary length of wire through the
connector.
Make all necessary wire connections and reattach the
cover plate to the outer shell.
If the box is being wired from the INSIDE of the appli-
ance:
Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to
disengage it from the outer shell.
Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
Feed the necessary length of wire through the
connector.
Make all necessary wire connections to the junction box/
receptacle and reassemble the junction box/receptacle
to the outer shell.
46
Figure 13.2 Junction Box Detail
Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
GRN wire
to GRN screw with
inside box
GRN wire

Advertisement