C. Junction Box Installation
If the box is being wired from the OUTSIDE of the appli-
ance:
•
Remove the cover plate located on the outer shell - right
side (see Figure 13.2).
•
Install the supplied Romex™ connector in the cover
plate.
•
Feed the necessary length of wire through the
connector.
•
Make all necessary wire connections and reattach the
cover plate to the outer shell.
If the box is being wired from the INSIDE of the appli-
ance:
•
Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to
disengage it from the outer shell.
•
Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
•
Feed the necessary length of wire through the
connector.
•
Make all necessary wire connections to the junction box/
receptacle and reassemble the junction box/receptacle
to the outer shell.
46
Figure 13.2 Junction Box Detail
Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
GRN wire
to GRN screw with
inside box
GRN wire