Light Glass Replacement/Cleaning
Frequency:
Annually
By:
Qualifi ed Service Technician
Tools
needed: Protective gloves
Disconnect power to fi replace.
Remove the "L" plates and inner surround frame (see
surround install). This will make the valve compartment
and glass accessible.
CAUTION! The surround kit is heavy.
two installers to move the frames.
Loosen the two thumb screws on the glass frame above
the LED light bar. See Figure 3.4.
Slide the frame forward and out. Unplug LED light bar
and remove glass frame assembly.
Ensure glass frame is clean of debris or replace if
needed..
Figure 3.4
Loosen Glass Frame
Reinstall glass frame. The frame must be hooked
on both shoulder screws on the fi rebox bottom. See
Figure 3.5.
Slide glass and gasket into glass frame ensuring the
glass is centered into inner frame.
Install both thumb screws through glass frame and into
fi rebox bottom.
Ensure the glass is fully seated and that the thumb
screws are tight.
Plug in light bar.
Reinstall "L" plates.
Shoulder
Screw
Figure 3.5
Reinstall Glass Frame
We recommend
Thumb Screws
Slot
Glass & Gasket
Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11
LED Light Bar Replacement
Frequency:
As needed
By:
Qualifi ed Service Technician
Tools
needed: Protective gloves, phillips screwdriver
Disconnect power to fi replace.
Remove the "L" plates and inner surround frame (see
surround install). This will make the valve compartment
and light bar accessible.
Remove the two screws securing the light bar on the
front of the bracket.
Release the 4-pin connector jumper wire between the
lights to remove the light strip.
Install new light bar (shown in Fig. 3.6).
Figure 3.6
Light Bar