See Section 15.A for instructions to remove fi xed glass
assembly.
Clean glass with a non-abrasive commercially available
cleaner.
- Light deposits: Use a soft cloth with soap and water
- Heavy deposits: Use commercial fi replace glass cleaner
(consult with your dealer)
Carefully set fi xed glass assembly in place on fi replace.
Hold glass in place with one hand and secure glass
latches with the other hand.
Reinstall inner frame and "L" pieces.
Doors, Surrounds, Fronts
Frequency:
Annually
By:
Homeowner
Tools
needed: Protective gloves, stable work surface
Assess condition of screen and replace as necessary.
Inspect for scratches, dents or other damage and repair
as necessary.
Check that openings are not blocked.
Vacuum and dust surfaces.
Remote Control
Frequency:
By:
Tools
instructions.
Locate remote control transmitter and receiver.
Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
Place batteries as needed in remote transmitters and
battery-powered receivers.
Place remote control out of reach of children.
If not using your fi replace for an extended period of time
(summer months, vacations/trips, etc), to prevent unin-
tended operation:
Remove batteries from remote controls.
Venting
Frequency:
By:
Tools
Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
Verify termination cap clearance to subsequent
construction (building additions, decks, fences, or
sheds). See Section 6.
Inspect for corrosion or separation.
Verify weather stripping, sealing and fl ashing remains
intact.
Inspect draft shield to verify it is not damaged or
missing.
Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11
Seasonally
Homeowner
needed: Replacement batteries and remote control
Seasonally
Homeowner
needed: Protective gloves and safety glasses.