Remote Maintenance by telnet

Important
❒ Remote Maintenance should be
password-protected so that access
is allowed to administrators only.
❒ The password is the same as the
one of Web Image Monitor admin-
istrator. When the password is
changed using "mshell", other
passwords change also.
❒ Some command cannot be set de-
pending on the model type.

Using telnet

Follow the procedure below to use
telnet.
Important
❒ Only one user at a time can log on
to perform remote maintenance.
A
Use the IP address or the host name
of the machine to start telnet.
% telnet IP_address
B
Enter your user name and pass-
word.
For details about the user name
and password, consult your net-
work administrator.
Note
❒ For user authentication, enter a
login user name and password.
❒ For user code authentication,
enter a user code in User Name.
C
Enter a command.
D
Quit telnet.
msh> logout
The configuration message about
saving the changes appears.
Remote Maintenance by telnet
E
Enter "yes" to save the changes,
and then press the {Enter} key.
If you do not want to save the chang-
es, enter "no", and then press the
{Enter} key. To make further chang-
es, enter "return" at the command
line, and then press the {Enter} key.
Note
❒ If the message "Can not write
NVRAM information" appears,
the changes are not saved. Re-
peat the procedure above.
❒ When the changes are saved, the
network interface board is reset
automatically with that changes.
❒ When the network interface
board resets, the print job in
print process will be printed.
However, print jobs in queue
will be canceled.

access

Use the "access" command to view
and configure access control. You can
also specify two or more access ranges.
❖ View settings
msh> access
❖ Configuration
msh> access ✩ range "start
-address end-address"
• ✩ represents a target number
between 1 and 5. (Up to five ac-
cess ranges can be registered
and selected.)
Example: to specify accessible IP
addresses between 192.168.0.10
and 192.168.0.20:
msh> access 1 range 192.
168.0.10 192.168.0.20
4
87