Damper
Damper Scale:
Lower Wash Spray
Arm Jet Force:
9. RELOCATION
1. Make sure the power supply is off before making any electrical connections
to prevent possible electric shock. Lockout/Tagout to prevent the power from
being turned back on inadvertently.
2. When draining the booster tank and hot water supply line at the time of
relocation, wait until the surface temperature falls below 104°F (40°C) to
avoid the risk of burns.
1) Shut down and clean the unit according
to the instruction manual.
2) Ask the detergent supplier to treat the
detergent and rinse aid tanks and pipes.
3) To drain the booster tank, remove the
front panel, take out the end of the drain
hose, and remove the plug.
4) Disconnect the electrical, water supply
and drain connections.
5) Move the unit with care not to damage it.
6) Reinstall the unit properly according to this installation
manual.
Lower Wash Pipe
3
2
High
Lower Wash
Spray Arm
1
Low
WARNING
Booster Tank
18
Screw
Damper
Drain Hose
Clamp
Plug