* If the drain pipe running from side to side at the bottom is long and coming out from
under the unit, the drain pipe weight may cause deformation of the wash tank bottom.
In such case, insert the accessory hook - drain into the square hole in the bottom of the
unit, secure with the bolt provided, and use a band to hold the drain pipe.
Drain Pipe
* Keep parallel to the unit

5. ELECTRICAL CONNECTION

1. Electrical connection must be hard-wired and must meet national, state, and
local electrical code requirements. Failure to meet these code requirements
FRXOG UHVXOW LQ GHDWK HOHFWULF VKRFN VHULRXV LQMXU\ ¿UH RU H[WHQVLYH GDPDJH
to equipment. A ground fault circuit interrupter (GFCI) must be installed to
meet these code requirements.
2. This unit requires independent power supplies for the dishwasher and for the
booster tank. See the nameplate for proper voltage and breaker/fuse sizes.
Failure to use proper breakers or fuses can result in tripped breakers, blown
IXVHV RU GDPDJH WR H[LVWLQJ ZLULQJ 7KLV FRXOG OHDG WR KHDW JHQHUDWLRQ RU ¿UH
3. THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit could
result in death or serious injury.
4. Make sure the power supply is off before making any electrical connections
to prevent possible electric shock. Lockout/Tagout to prevent the power from
being turned back on inadvertently.
* Installable at either side
WARNING
Bolt (M6 x 12)
10
Hook - Drain
Band
(not provided)