[C] Rinse Aid Inlet; [D] Signal (Power Supply) Connections - Hoshizaki JWE-2400CUA-L-25B Installation Manual

Hide thumbs Also See for JWE-2400CUA-L-25B:
Table of Contents

Advertisement

1RWH 'R QRW LQVWDOO WKH GHWHUJHQW LQOHW WR WKH ULQVH VSUD\ DUP VLGH ,I WKH GHWHUJHQW LQOHW
cannot be installed to the side of the tank, drill a mounting hole in the entrance of
the wash compartment or the back of the top panel.
Mounting Hole
Left Side
(JWE-2400CUA-L)

[c] RINSE AID INLET

Remove the front panel. Locate the rinse aid inlet at the end of the hose reaching from the
back of the rinse pump to the front of the unit.
Clamped to Frame

[d] SIGNAL (POWER SUPPLY) CONNECTIONS

1) Remove the front panel, open the slide cover on the base to
route the detergent and rinse aid feeder cables and the vent fan
control signal cable.
2) Connect the feeder cables to the terminal block on the side of
the control box. Connect the vent fan control signal cable (2A or
less) to the terminal block on the front of the wash pump motor
bracket. For details, see the wiring diagram below.
 &ORVH DQG VHFXUH WKH VOLGH FRYHU 5H¿W WKH IURQW SDQHO LQ LWV FRUUHFW SRVLWLRQ
* The vent fan control signal is emitted during the wash and rinse cycles (while the wash
pump or rinse pump is running).
Side Panel
Plug
JWE-2400CUA-L: back right
JWE-2400CUA-R: back left
14
Within This Area
 137
Rinse Spray Arm
Hose
Terminal Block

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jwe-2400cua-r-25b

Table of Contents