Hoshizaki JWE-2400CUA-L-25B Installation Manual page 16

Hide thumbs Also See for JWE-2400CUA-L-25B:
Table of Contents

Advertisement

AC Supply Voltage
208 - 230V / 60Hz / 3Ph
* Usually an electrical permit and services of a licensed electrician are required.
* The maximum allowable voltage variation is ±10 percent of the nameplate rating.
* The voltage tap switch on the right side of
the control box must be positioned to match
incoming voltage at startup (factory default:
230V).
* The opening for the power supply connection
LV ´ ',$ WR ¿W D ´ WUDGH VL]H FRQGXLW
* This dishwasher requires independent
power supplies for the dishwasher and for
the booster tank. Route the power supply
wires from the bottom of the dishwasher to
the two terminal blocks inside the control
box as follows:
1) Remove the front panel.
2) Remove the control box cover.
3) Connect the two ground wires to the two ground screws in the base.
 5RXWH SRZHU VXSSO\ ZLUHV QRW SURYLGHG LQWR WKH WZR ´ FRQGXLWV DW WKH ERWWRP RI
the unit, and then through the two top bushings on the right side of the control box.
Use the cable ties provided to bind the wires from inside the control box to prevent
disconnection.
The power supply wires must slope downward from the conduits to prevent
entrance of water through the bushing into the control box.
.HHS WKH ZLUH OHQJWK RI ´  PP EHWZHHQ WKH FRQGXLWV DQG WKH FRQWURO
box. The extra length allows the control box to be pulled out for service after
installation.
(OHFWULFDO 6SHFL¿FDWLRQV
$OVR 5HIHU WR WKH 'LVKZDVKHU 1DPHSODWH
Maximum Breaker/Fuse Size
Dishwasher 70A
Booster Tank 80A
WARNING
IMPORTANT
Minimum Circuit Ampacity
11
Dishwasher 70A
Booster Tank 80A
Control Box Cover
Voltage Tap
Switch
230V
Control Box
208V
Terminal Block