Ventilation - Hoshizaki JWE-2400CUA-L-25B Installation Manual

Hide thumbs Also See for JWE-2400CUA-L-25B:
Table of Contents

Advertisement

2) Put the cable of the accessory table limit switch through the cable hole in the dishtable,
and secure the switch with the bolts provided.
0.8" (20mm)
Cable Hole
1.34"
(34mm)
4.5"
(114mm)
2.93"
(74.5mm)
5.75"
(146mm)
3) Remove the front panel, open the slide cover on the base
to route the switch cable, then close and secure the slide
cover. Coil and tie any extra length of cable inside the
PDFKLQH FRPSDUWPHQW WR SUHYHQW FRQWDFW ZLWK WKH ÀRRU
4) Remove the plastic bag from the switch connection cable coming out of the control box,
and connect the 4P connector. Cover the cable connection with the plastic bag, and tie it
with the opening facing down.
5) Secure the cable with the wire retainer on the bottom of the unit.
 5H¿W WKH IURQW SDQHO LQ LWV FRUUHFW SRVLWLRQ

3. VENTILATION

1. Installation must be in accordance with applicable national, state, and local
regulations.
2. If an exhaust hood is required to discharge steam from the dishwasher, it
should provide a minimum 200 CFM at the entrance and 400 CFM at the
exit and be a listed and labeled factory-built commercial exhaust hood tested
in accordance with UL Standard 710 by a nationally recognized testing
laboratory.
It must be installed according to the terms of its listing and the manufacturer's
installation instructions.
8.1" (206mm)
Three 0.24" (6mm)
Mounting Holes
3.6"
(91mm)
5.9"
(150mm)
WARNING
6
0 %ROW  1XW
(provided)

Advertisement