If the new dryer
is installed
into an existing
exhaust
system
you must make
sure:
The exhaust system
meets all local, state, and national codes.
That a flexible plastic duct is not used.
To inspect and clean all lint buildup
from inside the existing
duct.
The duct is not dented
or crushed.
The exhaust
hood damper
opens and closes freely.
The static pressure
in any exhaust system
must not exceed 0.83 inches of water column,
or be less than 0.
This can be measured
with the dryer running with a manometer
at the point where the exhaust duct
connects
to the dryer. A no-heat setting
should
be used. The dryer tumbler
should be empty and the lint
filter clean.
IM PORTANT TO INSTALLER
Please read the following
instructions
carefully
before installing the dryer. These instructions
should
be kept
for future reference.
_
Remove the door from all discarded
appliances
to avoid the danger
of a child being trapped
and
WARN_,G
suffocating.
LOCATION
CONSl DERATIONS
The dryer should
be located where there is enough
space at the front for loading the dryer, and enough
space behind for the exhaust system. This dryer is factory-ready
for the rear exhaust option. To exhaust out
the bottom,
right or the left, use the accessory
exhaust kit. Instructions
are included
with the kit. Make sure
the room in which the dryer is located has enough fresh air. The dryer must be located where there are no
air-flow
obstruction.
For gas dryers, adequate
clearance
must be maintained
as noted on the data plate to ensure adequate
air
for combustion
and the proper
dryer operation.
The dryer must not be installed or stored
in an area where it will be exposed
to water and/or weather.
The
dryer area must be kept clear of combustible
materials,
gasoline,
and other flammable
vapors and liquids. A
dryer produces
combustible
lint. The area around the dryer should
be kept lint-free.
ALCOVE
OR CLOSET INSTALLATIONS
z_The
dryer must be exhausted
to the outside
to reduce the risk of fire when installed in an alcove or
W,_RN_G
closet.
No other fuel-burning
appliance
should
be installed in the same closet as the dryer.
WARNING:
To reduce the risk of fire, this dryer must be exhausted
to the outside.
Refer to "Exhausting"
section on page 16.
Minimum
clearances
between
the dryer and adjacent
walls or other surfaces
are: 2" in front, 17" on top,
1" on either side, and 8" at the back.
The front of the closet
must have two unobstructed
air openings
for a combined
minimum
total area
of 72 in2 with a minimum
clearance
of 3" at the top and bottom.
A slatted door with equivalent
space
clearances
is acceptable.
Installing