DUCTING
REQUIREMENTS
Use a 4-inch
(10.2 cm) diameter
rigid aluminum
or rigid galvanized
steel duct.
Do not use a smaller duct.
Ducts larger than 4 inches (10.2 cm) in diameter
can result in increased
accumulation
of lint.
Lint should
be removed
regularly.
If a flexible
metal duct must be used, use the type with a stiff sheet metal wall. Do not use a flexible duct
with a thin foil wall. A serious blockage
can result if the flexible metal duct is bent too sharply.
Never install any type of flexible duct in walls, ceilings,
or other concealed
spaces.
Keep the exhaust duct as straight
and short as possible.
Secure joints with duct tape. Do not use screws.
Do not use plastic flexible duct. Plastic flexible duct can kink, sag, be punctured,
reduce airflow, extend
drying times, and affect dryer operation.
Exhaust
systems longer than recommended
can extend drying times, affect machine
operations,
and
collect lint.
The exhaust duct should end with an exhaust hood with a swing-out
damper to prevent back drafts and
entry of wildlife.
Never use an exhaust hood with a magnetic
damper.
The hood should have at least 12 inches (30.5 cm) of clearance
between
the bottom
of the hood and
the ground
or other obstruction.
The hood opening should
point down.
Never install a screen over the exhaust
outlet.
To avoid lint buildup,
do not exhaust the dryer directly into a window
well. Do not exhaust
under a house
or porch.
If the exhaust duct must run through
an unheated
area, the duct should be insulated and slope slightly
down towards
the exhaust hood to reduce condensation
and lint buildup.
Inspect
and clean the interior of the exhaust system at least once a year. Unplug the power cord before
cleaning.
Check frequently
to make sure the exhaust
hood damper
opens and closes freely.
Check once per month, and clean at least once per year. Note: If your clothes are not getting dry, then
check the ducting for obstructions.
Do not exhaust the dryer into a wall, ceiling, crawl space, or concealed
space of a building,
gas vent, or
any other common
duct or chimney. This could create a fire hazard from the lint expelled by the dryer.
Weather
Hood Type
....
Recommended
Use only for shOre-run
installation
4" (10.16
cm)
2.5" (6.35 cm)
No. of 90
ebows
Rgd
Metallic
Flexible
Rigid
Metallic
Flexible
0
24.4 m (80 ft.)
12.4 m (41 ft.)
22.6 m (74 ft.)
10.1 m (33 ft.)
1
20.7 m (68 ft.)
11.2 m (37 ft.)
18.9 m (62 ft.)
8.8 m (29 ft.)
2
17.4 m (57 ft.)
10.1 m (33 ft.)
15.5 m (51 ft.)
7.6 m (25 ft.)
3
14.3 m (47 ft.)
9.0 m (29 ft.)
12.5 m (41 ft.)
6.5 m (21 ft.)
* Do not use non-metallic
flexible ducts.
14 Installing
your dwer
DV457E(GF02836E
ENindd
14
2012-04-09
D_4:15:41