Extron electronics CrossPoint 450 Plus Series User Manual page 42

Extron electronics matrix switchers user's manual
Hide thumbs Also See for CrossPoint 450 Plus Series:
Table of Contents

Advertisement

1
6
9
5
9-pin D
Connection
Pin 2
Computer's RX line
Pin 3
Computer's TX line
Pin 5
Computer's signal ground
Figure 2-24 — Optional 9-pin TRS RS-232 cable
This port is independent of the rear panel Remote port and is not affected by
changes to the rear panel port's protocol. This front panel port's protocol can
be changed, under SIS command control only. See the Command/Response
table for IP SIS commands, in chapter 4, "Programmer's Guide", to configure
all ports under SIS control.
A front panel Configuration port connection and a rear panel Remote port
connection can both be active at the same time.
This port is RS-232 only, with its default protocols as follows:
• 9600 baud
• no parity
• 1 stop bit
• no flow control
The maximum distances from the matrix switcher to the controlling device can
vary up to 200 feet (61 m). Factors such as cable gauge, baud rates,
environment, and output levels (from the switcher and the controlling device)
all affect transmission distance. Distances of about 50 feet (15 m) are typically
not a problem. In some cases the matrix switcher may be capable of serial
communications via RS-232 up to 250 feet (76 m) away.
CrossPoint 450 Plus and MAV Plus Switchers • Installation
6 feet
(1.8 m)
Part #70-335-01
TRS Plug
Tip
Ring
Sleeve
• 8 data bits
Tip
Ring
Sleeve (Gnd)
2-19