Extron electronics CrossPoint 450 Plus Series User Manual page 119

Extron electronics matrix switchers user's manual
Hide thumbs Also See for CrossPoint 450 Plus Series:
Table of Contents

Advertisement

Programmer's Guide, cont'd
Command/response table for SIS commands (Cont'd)
Command
I/O Grouping (Continued)
Read output grouping
The group that is assigned (
Save, recall, and directly write presets
If the user tries to recall a preset that is not saved, the matrix switcher responds with the
error code E11.
If the room is nonexistent, the matrix switcher responds with the error code E21.
The following characters are invalid in preset names:
+ ~ , @ = ' [ ] { } < > ' " ; : | \ and ?.
Save current ties as a global preset
Example:
Recall a global preset
Example:
Save current ties for a room
Example:
Direct write process —
The direct write of a global preset should always be preceded by a clear global preset
command of that same preset number, as shown below. In a directly-written preset, each output
position's tied input (or no tied input) remains unchanged unless overwritten or cleared.
If you do not clear a global preset number before you directly write a global preset to that
number, ties that are part of the previous version of the specified presets with the same number
can unexpectedly become part of the newly-created preset.
Clear a global preset
Directly write a global preset
Example:
Write room outputs
Each
A room can contain a maximum of 16 outputs.
An output can only belong to one room.
The maximum number of rooms (
If no room name is assigned, the default name is "Room #
Example:
4-12
CrossPoint 450 Plus and MAV Plus Switchers • Programmer's Guide
ASCII Command Response
(host to switcher)
(switcher to host)
O
Esc
X10
) must be 1, 2, 3, 4, or 0 (not grouped).
X10
,
Spr
X11
,
9
Spr09
.
Rpr
X11
.
5
Rpr05
,
*
Rmm
X8
X12
,
3*9
Rmm03•Spr09
+
P0*!
Spr
Esc
X11
+
P
*
!
*
%
Esc
X11
X2
X3
X2
X3
Spr
+27P2*5!10*9$13*11%3*10&
Esc
Spr27
,
,
,...
MR
Esc X8
Y1
Y2
Yn
Mpr
is an output
Y#
X8
8,3,04,5,6MR
Mpr8,03,04,05,06
Esc
Additional description
1
2
3
n
...
One
X10
X10
X10
starting from input 1, n is the
maximum number of inputs for
this model.
Command character is a comma.
X11
Save current ties as preset 9.
Command character is a period.
X11
Recall preset 5, which becomes
the current configuration.
•Spr
Command character is a comma.
X8
X12
Save current ties as preset 9 for
room 3.
Clear all ties in preset number
X11
*
$...
*
&
The tie all (!), tie RGBHV (&),
X2
X3
X2
X3
tie video (%), and tie audio ($)
X11
commands are all valid.
Brackets are shown to separate
ties for clarity only. Create global
preset 27, which ties video and
audio input 22 to output 5,
RGBHV input 15 to output 29,
video input 13 to output 26, and
audio input 3 to output 8.
,
,
,...
See notes.
X8
Y1
Y2
Yn
)is 10.
X*•Y!
•Y@
,
Outputs 3, 4, 5, and 6 are
assigned to room 8.
entry for each output,
X10
.
X11
•Y#
,
".

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mav plus series

Table of Contents