Cycle Selector Advances Through Off
• Extra
rinse
is selected.
Fills with the Wrong Temperature Water
• Turn both faucets on fully.
• Make sure temperature
selection is correct.
• If Auto Temperature
Control
is selected,
cold water may feel warmer
than cold water from the tap (see page 3).
• Make sure hoses are connected
to correct faucets and inlet COlmections.
Be sure water supply is regulated
correctl):
Flush water lhle before fillh_g washer.
• Check the water heater.
It should be set to deliver a mh_imum
120 ° F (49 ° C) hot water at the tap. Also check water
heater capacity and recovel T rate.
Disconnect
hoses and clean screens.
Hose filter screens may be plugged.
End of Cycle Chime Does Not Sound
• When Extended
Spin (select models)
is not selected, there may be a three-minute
delay before chime sounds.
This is
normal.
• End of Cycle Chime switch (select models) is set to Lo or Off.