Connections - EverFocus EDR-1610A Installation & Operation Manual

Digital video recorder
Table of Contents

Advertisement

1.5 CONNECTIONS

(1)
Main switch: Power switch, below IEC socket for 100~240 VAC power source
(2)
MAIN monitor: Main monitor for live and playback display and on-screen
display
(3)
CALL monitor: CALL monitor output. Spotmonitor for full screen live display,
sequence mode and alarm camera switching
(4)
Video inputs:
EDR910:
VIDEO IN(1~9): BNC video inputs for 1 Vpp Composite video signals,
automatic 75 Ohm termination (high impedance switching upon loop-through
output load)
EDR1610:
VIDEO IN (1~16): BNC video inputs for 1 Vpp Composite video signals,
automatic 75 Ohm termination (high impedance switching upon loop-through
output load)
(5)
Alarm and control inputs / outputs (for connection assignment, refer to
appendix C)
ALM-INPUT: 9 (EDR910) resp. 16 (EDR1610) alarm inputs for dry
contacts, programmable NO or NC in the menu.
ALM-OUTPUT: 1 x NO/NC alarm output relay
REC-IN: Input contact for recording start, NO, for dry contacts
(6)
LAN: RJ45 network socket
(7)
RS232 socket: 9-pin Sub-D control input/output for service purpose
(8)
RS485 socket: 2 x RJ45 socket (equal) for remote control via RS-485
keyboards and telemetry control (network-controlled)
(9)
VGA-output: optional VGA output for main monitor
(10) IR-extension socket: socket for IR extension cable EDA967(10m), EDA968
(20m)
- 10 -
EDR910_1610_ma_en_rev1 00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Edr-910aEdr-910dEdr-1610d

Table of Contents