3 • Configuring the T-DAC for operation
2. From the Line Coding pull-down menu
(figure
45), select dsx1B8ZS(2) or dsx1AMI(5).
Figure 45. Line Coding pull-down menu with dsx1B8ZS(2) selected
3. From the Line Build Out pull-down menu
(figure
46) select t1pulse0dB(1).
Figure 46. Line Build Out pull-down menu with t1pulse0dB(1) selected
4. Click on Submit Query to apply your settings.
At this point the WAN front panel LEDs will become active. The FRAME indicator LED should now display
a steady green light, indicating the T-DAC has synchronized with the E1 line. If the E1 line is not connected
to the 3196RC, T1/E1 link pages will display the hyperlink ALARMS PRESENT
(figure
47) for that T1/E1
link.
Figure 47. T1 ALARMS PRESENT indicator on T1/E1 LINK ACTIVITY page
After you connect the E1 line to the WAN port on the rear of the Model 3196RC, these alarms should disappear.
Using a browser to complete Model 3196RC configuration